The effect of vascular changes on the photoplethysmographic signal at different hand elevations.
نویسندگان
چکیده
In order to further understand the contribution of venous and arterial effects to the photoplethysmographic (PPG) signal, recordings were made from 20 healthy volunteer subjects during an exercise in which the right hand was raised and lowered with reference to heart level. Red (R) and infrared (IR) PPG signals were obtained from the right index finger using a custom-made PPG processing system. Laser Doppler flowmetry (LDF) signals were also recorded from an adjacent fingertip. The signals were compared with simultaneous PPG signals obtained from the left index finger. On lowering the hand to 50 cm below heart level, both ac and dc PPG amplitudes from the finger decreased (e.g. 18.70 and 63.15% decrease in infrared dc and ac signals respectively). The decrease in dc amplitude most likely corresponded to increased venous volume, while the decrease in ac PPG amplitude was due to regulatory adjustments on the arterial side in response to venous distension. Conversely, ac and dc PPG amplitudes increased on raising the arm above heart level. Morphological changes in the ac PPG signal are thought to be due to vascular resistance changes, predominately venous, as the hand position is changed.
منابع مشابه
Increasing the Accuracy of Blood Hematocrit Measurement by Triplicate Wavelength Photoplethysmography Method
Background and objectives: The importance of continuous monitoring and rapid and accurate informing of changes in blood components (e.g., percentage of hematocrit [HCT]), especially in acute conditions, has motivated researchers to use non-invasive measurement methods. Therefore, this study aimed to evaluate the association between blood HCT and photoplethysmographic signal and the possibility ...
متن کاملEffect of Echo Time on the Maximum Relationship between Contrast Agent Concentration and Signal Intensity Using FLAIR Sequence
Introduction Contrast-enhanced fluid-attenuated inversion recovery (FLAIR) is one of the MRI sequences that can be used for detection and evaluation of pathological changes in the brain. In this work, we have studied the effect of different echo times (TE) on the maximum relationship between signal intensity and concentration of the contrast agent using the FLAIR sequence. Materials and Methods...
متن کاملArterial Blood Oxygen Saturation during Blood Pressure Cuff-induced Hypoperfusion
Pulse oximetry has been one of the most significant technological advances in clinical monitoring in the last two decades. Pulse oximetry is a non-invasive photometric technique that provides information about the arterial blood oxygen saturation (SpO2) and heart rate, and has widespread clinical applications. When peripheral perfusion is poor, as in states of hypovolaemia, hypothermia and vaso...
متن کاملEffect of Phase-Encoding Reduction on Geometric Distortion and BOLD Signal Changes in fMRI
Introduction Echo-planar imaging (EPI) is a group of fast data acquisition methods commonly used in fMRI studies. It acquires multiple image lines in k-space after a single excitation, which leads to a very short scan time. A well-known problem with EPI is that it is more sensitive to distortions due to the used encoding scheme. Source of distortion is inhomogeneity in the static B0 field that ...
متن کاملبررسی اثرات عروقی تجویز مزمن 2 داروی سولفونیل اوره از نسل اول(کلرپروپامید) و نسل دوم(گلیبنکلامید) بر عملکرد آئورت سینهای موش صحرایی سالم
Diabetes mellitus is one of the most common endocrine disorders with increasing prevalence. Cardiovascular complications are among the major causes of death in diabetic patients. Type II diabetes mellitus is generally treated with sulfonylureas. There are controversial reports regarding adverse cardiovascular effects of these drugs. Also evidence exists about differences in side effec...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Physiological measurement
دوره 36 3 شماره
صفحات -
تاریخ انتشار 2015