The effect of gas plasma modification on platelet and contact phase activation processes.
نویسندگان
چکیده
Medical-grade polytetrafluoroethylene (PTFE), polydimethylsiloxane (PDMS), polyetherurethane (PEU) and ultrahigh molecular weight polyethylene (UHMWPE) were plasma treated with O2, Ar, N2 and NH3. Their surface properties were characterised using X-ray photoelectron spectroscopy (XPS), static secondary ion mass spectroscopy (SSIMS), atomic force microscopy (AFM) and dynamic contact angle (DCA) analysis. Platelet adhesion, aggregation, activation and release of microparticles were determined after contact with whole blood in a cone and plate viscometer. Activation of the coagulation system was quantified in a static environment using a partial thromboplastin time (PTT) assay. The chemical compositions of the untreated surfaces were found to be very similar to those of the bulk material except for PEU, whose surface was comprised almost entirely of soft ether segments. For all materials, the different plasma treatments resulted in moderate etching with the incorporation of functional groups and removal of side groups: defluorination, dehydrogenation, cleavage of methyl side groups and soft segments for PTFE, UHMWPE, PDMS and PEU, respectively. Consequently, plasma treatment resulted in increased wettability in all cases. Blood contact with the virgin materials resulted in activation of platelets and the clotting cascade. Plasma treatment resulted in a significant reduction in platelet adhesion for all materials and all treatments. In the case of PTFE and PEU, the activation status of these cells was also reduced. Plasma treatment of all materials reduced fluid-phase CD62P expression. Platelet aggregate size correlated well with degree of aggregate formation, but many treatments increased the degree of aggregation, as was the case for microparticle shedding. There was no correlation between CD62P expression, aggregate formation and platelet microparticle (PMP) shedding. It is concluded that despite incorporation of the same chemical groups, the pattern of response to blood in vitro is not the same across different polymers.
منابع مشابه
Comparison of the thickening of donor skin graft with conventional method (using vaseline gas) and platelet-rich plasma topical application
Background: Healing involves complex processes that are not yet fully known. The wound healing process consists of three stages. In all these stages, normal wound healing requires platelet activation, release of cytokines and growth hormones, and chemotaxis and cell differentiation. Platelets play a key role in homeostasis and wound healing and growth factor production of more than 30 carried o...
متن کاملتاثیر فیلتراسیون پیش از ذخیره کردن بر فعال شدن پلاکتها در فراوردههای پلاکتی
Preparation conditions and platelet storage for transfusion may cause platelet activation, which contributes to decreased ability of stored platelet to function and survive in vivo after transfusion compared with that seen with freshly prepared platelets. Using flowcytometry, we investigated platelet membrane expression of CD62P, CD63 in platelet stored for up to 3 days under standard blood ba...
متن کاملImprovement of gas separation properties of polyurethane membrane using plasma grafting
In recent years, plasma treatments have given good results since they offer high technological efficiency with low waste generation. One of the most important characteristics of plasma methods is their action only on a thin surface layer, whereas the bulk of sample remains unchanged and the modified material keeps its chemical and mechanical properties. In this research, polyurethane membrane s...
متن کاملAn Overview on Platelet-derived Microparticles in Platelet Concentrates: blood collection, method preparation and storage
Preparations of platelet concentrates (PCs) that are stored under blood bank conditions and used for transfusion purposes, appear to be enriched in platelet derived-microparticles (PMPs) with high coagulant activity that may change platelet efficacy and safety issues. High shear stress could cause shedding of PMPs from the platelet plasma membrane, platelet aggregation, and activation of the co...
متن کاملSurface modification of a segmented polyetherurethane using a low-powered gas plasma and its influence on the activation of the coagulation system.
A medical grade segmented polyetherurethane (PEU) was treated with a low-powered gas plasma using O(2), Ar, N(2) and NH(3) as the treatment gases. Changes in the surface functional group chemistry were studied using X-ray photoelectron spectroscopy. The wettability of the surfaces was examined using dynamic contact angle measurements and the surface morphology was evaluated using atomic force m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Biomaterials
دوره 28 31 شماره
صفحات -
تاریخ انتشار 2007