چکیده

The Brandaris 128 ultra-high-speed imaging facility has been updated over the last 10 years through modifications made to the camera's hardware and software. At its introduction the camera was able to record 6 sequences of 128 images (500 × 292 pixels) at a maximum frame rate of 25 Mfps. The segmented mode of the camera was revised to allow for subdivision of the 128 image sensors into arbitrary segments (1-128) with an inter-segment time of 17 μs. Furthermore, a region of interest can be selected to increase the number of recordings within a single run of the camera from 6 up to 125. By extending the imaging system with a laser-induced fluorescence setup, time-resolved ultra-high-speed fluorescence imaging of microscopic objects has been enabled. Minor updates to the system are also reported here.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Brandaris 128: A digital 25 million frames per second camera with 128 highly sensitive frames

A high-speed camera that combines a customized rotating mirror camera frame with charge coupled device ~CCD! image detectors and is practically fully operated by computer control was constructed. High sensitivity CCDs are used so that image intensifiers, which would degrade image quality, are not necessary. Customized electronics and instruments were used to improve the flexibility and control ...

متن کامل

طراحی شبکه برای حلقه انبارش چشمه نور ایران

The Iranian Light Source Facility (ILSF) as a national project is a 3 GeV third generation synchrotron light source facility which provides high energy super bright X-ray for the users. Design of the ILSF storage ring emphasizes an ultra low electron beam emittance (below than 5 nm.rad), beam current of 400 mA, great brightness, stability and reliability which make it competitive in the operati...

متن کامل

Optimization of an ultra-high-resolution rectangular pixelated parallel-hole collimator with a CZT pixelated semiconductor detector for HiRe-SPECT system

Introduction: In nuclear medicine, the use of a pixelated semiconductor detector such as CZT is an of growing interest for introducing new devices. Especially, the spatial resolution can be improved by using a pixelated parallel-hole collimator with equal holes and pixel sizes based on the pixelated detector. The purpose of this study was to compare the effect of pixelated and ...

متن کامل

High Framerate Imaging of Ultrasound Contrast Agents

Phospholipid-coated ultrasound contrast agents may deflate or even collapse because of stress resulting from ultrasound-induced oscillations. In this work we investigate the behavior of isolated contrast agent microbubbles during prolonged ultrasound excitation. Isolated microbubbles placed in a thin capillary tube were excited with hundreds of ultrasound pulses at a low mechanical index, and t...

متن کامل

Impact of Novel Incorporation of CT-based Segment Mapping into a Conjugated Gradient Algorithm on Bone SPECT Imaging: Fundamental Characteristics of a Context-specific Reconstruction Method

Objective(s): The latest single-photon emission computed tomography (SPECT)/computed tomography (CT) reconstruction system, referred to as xSPECT Bone™, is a context-specific reconstruction system utilizing tissue segmentation information from CT data, which is called a zone map. The aim of this study was to evaluate theeffects of zone-map enhancement incorporated into the ordered-subset conjug...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 83 10  شماره 

صفحات  -

تاریخ انتشار 2012