Determination of vitamin D status by radioimmunoassay with an 125I-labeled tracer.

نویسندگان

  • B W Hollis
  • J Q Kamerud
  • S R Selvaag
  • J D Lorenz
  • J L Napoli
چکیده

We report here the first radioimmunoassay for a vitamin D metabolite utilizing a radioiodinated tracer. Antibodies were generated in a goat immunized with the vitamin D analog 23, 24, 25, 26, 27-pentanor-C(22)-carboxylic acid of vitamin D, coupled directly with bovine serum albumin. The 125I-labeled tracer was prepared by reacting a 3-amino-propyl derivative of vitamin D-C(22)-amide with Bolton-Hunter reagent. The primary antiserum, used at a 15,000-fold final dilution, cross-reacted equally with all cholecalciferol and ergocalciferol metabolites tested except 1,25-dihydroxycalciferol metabolites and the parent calciferols; the antiserum did not cross-react with dihydrotachysterol. Calibrators were prepared in vitamin D-stripped human serum. 25-Hydroxycholecalciferol was quantitatively extracted from serum or plasma (50 microL) with acetonitrile. The assay consists of a 90-min incubation at room temperature with primary antiserum, followed by a 20-min incubation with a second antiserum and separation of bound from free fractions by centrifugation. The detection limit of the assay was 2.8 micrograms/L for 25-hydroxycholecalciferol. Results with the present assay compared well with those from a liquid-chromatographic procedure involving specific ultraviolet detection of 25-hydroxycalciferol in plasma.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of radioimmunoassay technique for determination of antigen concentration in different cells with a new monoclonal antibody [Persian]

Introduction: Binding a monoclonal antibody to tumor associated antigens is an effective method for cancer therapy because these agents can specifically target malignant cells, in fact monoclonal antibodies are effective agents for diagnosis, grading and treatment of different kinds of cancers. Methods: In this research, a new monoclonal antibody against colon cancer cells was prepared an...

متن کامل

Reduced variation of tracer binding in digoxin radioimmunoassay by use of (125I)-labeled tyrosine-methyl-ester derivative: relation of thyroxine concentration to binding.

Between-sample variation in tracer binding in the 125I-labeled digoxin radioimmunoassay was investigated with two tracers, 3-O-succinyl-digoxigenin-[125I]-labeled tyrosine and [125I]-labeled tyrosine-methyl-ester-digoxin. Digoxin-free serum samples having various concentrations of thyroxine were assayed with both tracers. The percentage of tracer bound when the samples were assayed with the fir...

متن کامل

One-step synthesis of a cortisol derivative for radioiodination and application of the 125I-labeled cortisol to radioimmunoassay.

A one-step synthesis of a cortisol derivative for radioiodination is presented. The radioimmunoassay for cortisol using the bridge heterologous 125I-labeled antigen was more sensitive than that using a bridge homologous antigen. Cortisol levels in saliva and serum were easily determined by direct radioimmunoassay with the proposed 125I-labeled antigen.

متن کامل

Assessment of epidermal growth factor receptor status in glioblastomas

Objective(s): Our previous study showed that a newly designed tracer radioiodinated 6-(3-morpholinopropoxy)-7-ethoxy-4-(3'-iodophenoxy)quinazoline ([125I]PYK) is promising for the evaluation of the epidermal growth factor receptor (EGFR) status and prediction of gefitinib treatment of non-small cell lung cancer. EGFR is over-expressed and mutated also in glioblastoma. In the present study, the ...

متن کامل

A strategy for radioimmunoassay of plasma progesterone with use of a homologous-site 125I-labeled radioligand.

In this sensitive, specific 125I radioimmunoassay for plasma progesterone, an identical glucuronide bridge is used in the immunogen and radioligand. This apparently provides a system in which the bridge is poorly recognized and thereby avoids the excessively high affinity of the tracer for the antiserum and the consequent poor sensitivity that commonly is found in other homologous-bridge situat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 39 3  شماره 

صفحات  -

تاریخ انتشار 1993