A prototype small‐bore ventilation catheter with a cuff: cuff inflation optimizes ventilation with the Ventrain

نویسندگان

  • M W P de Wolf
  • T van der Beek
  • A E Hamaekers
  • M Theunissen
  • D Enk
چکیده

BACKGROUND Ventilation through small-diameter tubes typically precludes use of a cuff as this will impede the necessary passive outflow of gas alongside the tube's outer surface. Ventrain assists expiration and enables oxygenation and normoventilation through small-bore cannulas or catheters, particularly in obstructed airways. A small-bore ventilation catheter (SBVC; 40 cm long, 2.2 mm inner diameter) with a separate pressure monitoring lumen and a cuff was developed. Efficacy of oxygenation and ventilation with Ventrain through this catheter was investigated in sealed and open airways in a porcine cross-over study. METHODS Six pigs were ventilated with Ventrain (15 l/min oxygen, frequency 30 breaths per min, I : E-ratio 1 : 1) through the SBVC, both with the cuff inflated and deflated. Prior to each test they were ventilated conventionally until steady state was achieved. RESULTS With an inflated cuff, PaO2 rose instantly and remained elevated (median [range] PaO2 61 [52-69] kPa after 30 min; P = 0.027 compared to baseline). PaCO2 remained stable at 4.9 [4.2-6.2] kPa. After cuff deflation, PaO2 was significantly lower (9 [5-28] kPa at 10 min, P = 0.028) and interventional ventilation had to be stopped prematurely in five pigs as PaCO2 exceeded 10.6 kPa. Pulmonary artery pressures increased markedly in these pigs. Intratracheal pressures were kept between 5 and 20 cmH2 O with the cuff inflated, but never exceeded 2 cmH2 O after cuff deflation. CONCLUSION The SBVC combines the benefits of a small diameter airway and a cuff. Cuff inflation optimizes oxygenation and ventilation with Ventrain.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Emergency ventilation with the Ventrain® through an airway exchange catheter in a porcine model of complete upper airway obstruction

PURPOSE During difficult airway management, oxygen insufflation through airway-exchange and intubating catheters (AEC/IC) can lead to life-threatening hyperinflation. Ventrain® was originally designed to facilitate emergency ventilation using active expiration through short, small-bore cannulas. Herein, we studied its efficacy (oxygenation and ventilation) and safety (avoidance of hyperinflatio...

متن کامل

بررسی تاثیر تغییر وضعیت بدن بر فشار کاف لوله تراشه در بیماران تحت تهویه مکانیکی

Background: Endotracheal tube cuff pressure must be maintained in safe range. Many factors could be affecting on endotracheal tube cuff pressure in patients on mechanical ventilation. Patients undergoing mechanical ventilation (MV) in critical care settings require changing position for different reasons. The aim of this study was to determine the effect of changes in body position and head of ...

متن کامل

Oxygen jet ventilation for microlaryngoscopic procedures.

Sir,—Intermittent jets of oxygen may be used to ventilate patients undergoing microlaryngoscopy with a Venturi injector or by flushing oxygen directly through a small-bore endotracheal tube as we have used in 10 adult patients (table I). The patients were premedicated with pethidine 75 mg and atropine 0.6 mg and anaesthesia was induced with propanidid 250-500 mg followed by suxamethonium 100 mg...

متن کامل

Transtracheal ventilation with a novel ejector-based device (Ventrain) in open, partly obstructed, or totally closed upper airways in pigs.

BACKGROUND Transtracheal access and subsequent jet ventilation are among the last options in a 'cannot intubate-cannot oxygenate' scenario. These interventions may lead to hypercapnia, barotrauma, and haemodynamic failure in the event of an obstructed upper airway. The aim of the present study was to evaluate the efficacy and the haemodynamic effects of the Ventrain, a manually operated ventila...

متن کامل

Study of endotracheal tube cuff pressure and time of measurement among intensive care units patients

Introduction: The pressure in the endotracheal tube cuff must be kept within an optimal range, to make sure tracheal capillaries circulation still stable during positive ventilation. This is essential to avoid oral and gastric stuffing aspiration Objective: The objective of this study was to assess the endotracheal tube cuff pressure and time intervals measurements among intensive care units...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 62  شماره 

صفحات  -