Potential pitfalls of functional MRI using conventional gradient-recalled echo techniques.
نویسندگان
چکیده
The conventional gradient-recalled echo technique, FLASH, has widely been used for functional MRI. FLASH results at 4 T with short TEs of 10-20 ms mimic those at 1.5 T with TEs of 25-50 ms or longer. Under these conditions, large venous vessels dominate the activated area; however, the use of longer TEs at 4 T reveals activation in gray matter areas as well as large vessels. Inflow effects of large vessels can be greatly reduced with centric-reordering of phase-encoding steps and inter-image delay. Finger and toe movement paradigms show that functional activation maps are consistent with classical somatotopic maps, and are specific to the tasks. Navigator-based motion correction generates functional maps with larger activation areas by reducing physiological noise.
منابع مشابه
اندازه گیری غیریکنواختی امواج رادیوئی در ام آر آی
Introduction: Non-uniformity is one of the most important parameters affecting MRI images which can lead to harmful effects in the diagnosis and analysis of qualitative and quantitative methods. The present study introduced a method for measuring RF non-homogeneity in MRI systems. Methods and Materials: To verify the uniformity of B0 and B1 fields, a cylindrical phantom with a diameter of 24 c...
متن کاملNon-invasive quantification of liver fat content by different Gradient Echo MRI sequences in patients with Non-Alcoholic Fatty Liver Disease (NAFLD)
Introduction: Non-invasive quantification of liver fat by Gradient echo (GRE) Technique is an interesting issue in quantitative MRI. Despite the numerous advantages of this technique, fat measurement maybe biased by confounding and effects. The aim of this study was to evaluate the GRE pulse sequences with different and weighting for liver fat quantification in patients with...
متن کاملCompressed Sensing for fMRI: Feasibility Study on the Acceleration of Non-EPI fMRI at 9.4T
Conventional functional magnetic resonance imaging (fMRI) technique known as gradient-recalled echo (GRE) echo-planar imaging (EPI) is sensitive to image distortion and degradation caused by local magnetic field inhomogeneity at high magnetic fields. Non-EPI sequences such as spoiled gradient echo and balanced steady-state free precession (bSSFP) have been proposed as an alternative high-resolu...
متن کاملSSFP and GRE phase contrast imaging using a three-echo readout.
A technique for rapid in-plane phase-contrast imaging with high signal-to-noise ratio (SNR) is described. Velocity-encoding is achieved by oscillating the readout gradient, such that each 2DFT phase-encode is acquired three times following a single RF slice-selective excitation. Three images are reconstructed, from which both flow velocity and local resonance offset are calculated. This techniq...
متن کاملSignal and noise characteristics of SSFP FMRI: A comparison with GRE at multiple field strengths
Recent work has proposed the use of steady-state free precession (SSFP) as an alternative to the conventional methods for obtaining functional MRI (FMRI) data. The contrast mechanism in SSFP is likely to be related to conventional FMRI signals, but the details of the signal changes may differ in important ways. Functional contrast in SSFP has been proposed to result from several different mecha...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- NMR in biomedicine
دوره 7 1-2 شماره
صفحات -
تاریخ انتشار 1994