Technical note: validation of a model for online classification of US Select beef carcasses for longissimus tenderness using visible and near-infrared reflectance spectroscopy.

نویسندگان

  • S D Shackelford
  • T L Wheeler
  • M Koohmaraie
چکیده

The present experiment was conducted to provide a validation of a previously developed model for online classification of US Select carcasses for LM tenderness based on visible and near-infrared (VISNIR) spectroscopy and to determine if the accuracy of VISNIR-based tenderness classification could be enhanced by making measurements after postmortem aging. Spectroscopy was conducted online, during carcass grading, at a large-scale commercial fed beef-processing facility, and the strip loin was obtained from the left side of US Select carcasses (n = 467). Slice shear force (SSF) was measured on fresh steaks at 2 and 14 d postmortem. Online VISNIR tenderness classes differed in mean SSF values at both 2 d (29.4 vs. 33.6 kg) and 14 d (18.0 vs. 21.2 kg) postmortem (P < 10(-7)). Online VISNIR tenderness classes differed in both the percentage of carcasses with LM SSF values greater than 40 kg at 2 d postmortem (5.1 vs. 21.0%; P < 10(-6)) and the percentage of carcasses with LM SSF values greater than 25 kg at 14 d postmortem (6.8 vs. 23.2%; P < 10(-5)). Whereas 15.0% of the carcasses sampled for this experiment had LM SSF values greater than 25 kg at 14 d postmortem, only 6.8% of the carcasses classified as tender by VISNIR had LM SSF values greater than 25 kg. All the carcasses sampled that had LM SSF values greater than 35 kg at 14 d postmortem were accurately classified as tough by VISNIR. Before measurement of SSF on d 14, VISNIR spectroscopy was conducted on the SSF steak. Tenderness classes based on d 14 VISNIR spectra differed both in mean SSF value at 14 d postmortem (17.7 vs. 21.6 kg; P < 10(-11)) and the percentage of carcasses with LM SSF values greater than 25 kg at 14 d postmortem (7.3 vs. 22.7%; P < 10(-5)). These data support our previous work showing that VISNIR spectroscopy can be used to classify US Select carcasses noninvasively for LM tenderness, and the results establish that this technology could also be applied to aged US Select strip loins. This technology would allow packing companies and other segments of the beef marketing chain to identify US Select carcasses or strip loins that excel in LM tenderness for use in branded beef programs.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

On-line classification of US Select beef carcasses for longissimus tenderness using visible and near-infrared reflectance spectroscopy.

The current experiment was conducted to evaluate the on-line application of visible and near-infrared spectroscopy (VISNIR) to US Select carcasses during commercial beef carcass grading procedures to predict tenderness of longissimus steaks after 14 days of refrigerated storage. A regression model was calibrated using 146 carcasses and tested against an additional 146 carcasses. Carcasses were ...

متن کامل

Field testing of a system for online classification of beef carcasses for longissimus tenderness using visible and near-infrared reflectance spectroscopy.

The present experiments were conducted to field test a system optimized for online prediction of beef LM tenderness based on visible and near-infrared (VISNIR) spectroscopy and to develop and validate a model for prediction of tenderness that would be unbiased by normal variation in bloom time before application of VISNIR. For both Exp. 1 and 2, slice shear force (SSF) was measured on fresh (ne...

متن کامل

Near-infrared reflectance analysis for predicting beef longissimus tenderness.

Near-infrared reflectance spectra (1,100 to 2,498 nm) were collected on beef longissimus thoracis steaks for the purpose of establishing the feasibility of predicting meat tenderness by spectroscopy. Partial least squares (PLS) analysis (up to 20 factors) and multiple linear regression (MLR) were used to predict cooked longissimus Warner-Bratzler shear (WBS) force values from spectra of steaks ...

متن کامل

Development of near infrared reflectance spectroscopy (NIRS) calibration model for estimation of oil content in a worldwide safflower germplasm collection

The development of NIRS calibration model as a rapid, precise, robust, and cost-effective method to estimate oil content in ground seeds of worldwide safflower germplasm collection grown under different agro-climatic conditions was the key objective of this research project. The oil content was measured by accelerated solvent extraction method in a total of 328 samples collected across 2004 (16...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of animal science

دوره 90 3  شماره 

صفحات  -

تاریخ انتشار 2012