High-resolution three-dimensional-pQCT images can be an adequate basis for in-vivo microFE analysis of bone.
نویسندگان
چکیده
Micro-finite element (microFE) models based on high-resolution images have enabled the calculation of elastic properties of trabecular bone in vitro. Recently, techniques have been developed to image trabecular bone structure in vivo, albeit at a lesser resolution. The present work studies the usefulness of such in-vivo images for microFE analyses, by comparing their microFE results to those of models based on high-resolution micro-CT (microCT) images. Fifteen specimens obtained from human femoral heads were imaged first with a 3D-pQCT scanner at 165 microns resolution and a second time with a microCT scanner at 56 microns resolution. A third set of images with a resolution of 165 microns was created by downscaling the microCT measurements. The microFE models were created directly from these images. Orthotropic elastic properties and the average tissue von Mises stress of the specimens were calculated from six FE-analyses per specimen. The results of the 165 microns models were compared to those of the 56 microns model, which was taken as the reference model. The results calculated from the pQCT-based models, correlated excellent with those calculated from the reference model for both moduli (R2 > 0.95) and for the average tissue von Mises stress (R2 > 0.83). Results calculated from the downscaled micro-CT models correlated even better with those of the reference models (R2 > 0.99 for the moduli and R2 > 0.96 for the average von Mises stress). In the case of the 3D-pQCT based models, however, the slopes of the regression lines were less than one and had to be corrected. The prediction of the Poisson's ratios was less accurate (R2 > 0.45 and R2 > 0.67) for the models based on 3D-pQCT and downscaled microCT images respectively). The fact that the results from the downscaled and original microCT images were nearly identical indicates that the need for a correction in the case of the 3D-pQCT measurements was not due to the voxel size of the images but due to a higher noise level and a lower contrast in these images, in combination with the application of a filtering procedure at 165 micron images. In summary: the results of microFE models based on in-vivo images of the 3D-pQCT can closely resemble those obtained from microFE models based on higher resolution microCT system.
منابع مشابه
High-Resolution Peripheral Quantitative Computed Tomography Can Assess Microstructural and Mechanical Properties of Human Distal Tibial Bone
High-resolution peripheral quantitative computed tomography (HR-pQCT) is a newly developed in vivo clinical imaging modality. It can assess the 3D microstructure of cortical and trabecular bone at the distal radius and tibia and is suitable as an input for microstructural finite element (microFE) analysis to evaluate bone's mechanical competence. In order for microstructural and image-based mic...
متن کاملEstimation of distal radius failure load with micro-finite element analysis models based on three-dimensional peripheral quantitative computed tomography images.
There is increasing evidence that, in addition to bone mass, bone microarchitecture and its mechanical load distribution are important factors for the determination of bone strength. Recently, it has been shown that new high-resolution imaging techniques in combination with new modeling algorithms based on the finite element (FE) method can account for these additional factors. Such models thus...
متن کاملIndividual Trabeculae Segmentation (ITS)–Based Morphological Analysis of High-Resolution Peripheral Quantitative Computed Tomography Images Detects Abnormal Trabecular Plate and Rod Microarchitecture in Premenopausal Women With Idiopathic Osteoporosis
Idiopathic osteoporosis (IOP) in premenopausal women is a poorly understood entity in which otherwise healthy women have low-trauma fracture or very low bone mineral density (BMD). In this study, we applied individual trabeculae segmentation (ITS)-based morphological analysis to high-resolution peripheral quantitative computed tomography (HR-pQCT) images of the distal radius and distal tibia to...
متن کاملAge- and Gender-Related Differences in the Geometric Properties and Biomechanical Significance of Intracortical Porosity in the Distal Radius and Tibia
Cortical bone contributes the majority of overall bone mass and bears the bulk of axial loads in the peripheral skeleton. Bone metabolic disorders often are manifested by cortical microstructural changes via osteonal remodeling and endocortical trabecularization. The goal of this study was to characterize intracortical porosity in a cross-sectional patient cohort using novel quantitative comput...
متن کاملNoninvasive Stem Cell Labeling Using USPIO Technique and their Detection with MRI
Background: To date, several imaging techniques to track stem cells are used such as positron emission tomography (PET), single photon emission computed tomography (SPECT), Bioluminescence imaging (BLI), fluorescence imaging, CT scan and magnetic resonance imaging (MRI). Although, overall sensitivity of MRI compared to SPECT and Bioluminescence techniques are lower, but due to high spatial reso...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of biomechanical engineering
دوره 123 2 شماره
صفحات -
تاریخ انتشار 2001