The actual status of acrylic bone cement in total hip replacement. A review.
نویسندگان
چکیده
The utilization of polymethylmethacrylate to sta· hilize· total hip replacements has tremendously in· creased since Charnley introduced the acrylic cement as a fixative in 1960. M~ny contemporary studies and experiments have resulted in increased knowledge about cement pro· perties and side.effects. In tbis article the present status of acrylic cement in total hip replacement is contemplated, with the aid of a comprehensive and actual review of the Uierature, and supplemented with remarks and recommendations resulting from a longlasting expe· rience with cemented hip arthroplasties in our clinic. Native knowledge of mixing and handling instruc· tions regarding the application of each separate cement is indespensable, while also the importance of practising meticulous cementing techniques in order to obtain optimal primary implant fixation, is .strongly emphasized. When hip replacements are performed according to these developments, a reduc· tion of mechanical loosening of cemented hip arthro· plasties is liable to be achieved.
منابع مشابه
The Use of Antibiotic Impregnated Cement Spacers in the Treatment of Infected Total Joint Replacement: Challenges and Achievements
Two stage total hip arthroplasty revision surgery includes foreign material debridment, insertion of antibiotic impregnatedcement spacer, and finally, reimplantation of the prosthesis. This review has aimed to evaluate the efficacy of antibioticimpregnated cement spacers in infection control and eradication in arthroplasties.A total of 85 articles on total hip arthroplasty wer...
متن کاملIntracardiac Foreign Body Formation from Bone Cement Material Following Total Hip Replacement: A Case Report
head and femoral canal have usually been involved in a procedure of total hip replacement (THR). Severe complications resulting from this procedure are infrequent. However, this procedure can cause localized problems such as infection or cement leakage into the femoral vein to inferior vena cava. We report a case of symptomatic foreign body formation in the right cardiac chambers caused by acry...
متن کاملThe temperature problem at the bone-acrylic cement interface of the total hip replacement.
Loosening of total joint replacements may be caused in part by thermal necrosis of bone in contact with the high temperature of the polymerizing PMMA acrylic cement. This study reports a method to reduce the temperature of the bone-cement interface below the temperature at which bone results in definite necrosis. By precooling the acetubular component to --84 degrees before insertion into the c...
متن کاملGeneral anaesthesia and total hip replacement.
TOTAL HIP REPLACEMENT has become a frequent procedure since the initial work of Charnley, McKee, Watson, Ferrar and Ring in the early 1960s. The most popular technique, that of Miiller, ~ involves a socket prosthesis fixed in the acetabulum with acrylic bone cement. A femoral prosthesis is then fixed in the medullary cavity with the same acrylic cement. Peroperative complications associated wit...
متن کاملDynamic creep behavior of acrylic bone cement.
Recent studies concerning the fixation of cemented total hip arthroplasty (THA) have led to new hypotheses about the dynamic, long-term failure mechanisms leading to prosthetic loosening. As a result, the long-term mechanical behavior of acrylic bone cement has gained more interest since little is known about these properties. In this study, the dynamic, compressive creep deformation of acrylic...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Acta orthopaedica Belgica
دوره 53 1 شماره
صفحات -
تاریخ انتشار 1987