Cone-Beam CT with a Flat-Panel Imager: Noise Considerations for Fully 3-D Computed Tomography

نویسندگان

  • Jeffrey H. Siewerdsen
  • David A. Jaffray
چکیده

Application of flat-panel imagers (FPIs) in cone-beam computed tomography (CBCT) offers a promising new modality for fully three-dimensional (3-D) x-ray imaging. Understanding the potential performance and fundamental limitations of such technology, however, requires knowledge of the noise characteristics of the 3-D imaging system. The noise performance of a prototype flat-panel cone-beam CT (FPI-CBCT) system is investigated empirically and theoretically in terms of voxel noise, noise-power spectrum (NPS), and detective quantum efficiency (DQE). Methods for NPS analysis common in characterizing 2-D imagers are extended to the fully 3-D case, and a general framework for NPS analysis in n dimensions is presented, including the important considerations of NPS convergence and normalization within the constraints of system linearity and stationarity. Factors affecting imager noise and NPS are numerous, including exposure, number of views, image blur, additive noise, reconstruction filter, and sampling matrix. The applicability of existing theoretical descriptions of CT voxel noise is examined. A theoretical cascaded systems model that accurately predicts the 2-D noise characteristics of the FPI is extended to describe the signal and noise transfer characteristics of the fully 3-D FPI-CBCT system employing filtered back-projection. Analysis of the fully 3-D NPS reveals features of the 3-D imaging system that might otherwise be missed and shows the significant effect of 3-D noise aliasing. Furthermore, it quantifies the performance of various FPI designs in CBCT (e.g., direct and indirect detectors, and variations therein) and provides a guide for the development of high-performance FPI-CBCT systems suited to specific clinical objectives.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cone-beam computed tomography with a flat-panel imager: initial performance characterization.

The development and performance of a system for x-ray cone-beam computed tomography (CBCT) using an indirect-detection flat-panel imager (FPI) is presented. Developed as a bench-top prototype for initial investigation of FPI-based CBCT for bone and soft-tissue localization in radiotherapy, the system provides fully three-dimensional volumetric image data from projections acquired during a singl...

متن کامل

The influence of antiscatter grids on soft-tissue detectability in cone-beam computed tomography with flat-panel detectors.

The influence of antiscatter x-ray grids on image quality in cone-beam computed tomography (CT) is evaluated through broad experimental investigation for various anatomical sites (head and body), scatter conditions (scatter-to-primary ratio (SPR) ranging from approximately 10% to 150%), patient dose, and spatial resolution in three-dimensional reconstructions. Studies involved linear grids in c...

متن کامل

Quality of Temporal Bone CT Images: A Comparison of Flat Panel Cone Beam CT and Multi-slice CT

Computed tomography (CT) of the temporal bone is used routinely in otology clinics. The development of multi-slice helical CT (MSCT) has improved the quality of images of the temporal bone and enhanced diagnostic competence significantly . However, MSCT images of minute bony structures in the temporal bone are not always clear enough to allow an accurate diagnosis and images of metal implants a...

متن کامل

Guest Editorial Fully 3-D Reconstruction of Medical Images

T ODAY, the majority of biomedical tomography systems on the market (e.g., modern positron emission tomog-raphy (PET), single photon emission computed tomography (SPECT), and X-ray cone-beam computed tomography (CT) devices) acquire projection data in 3-D mode. The detectors these devices employ have an axial extent which seems to increase steadily with the introduction of new systems. This all...

متن کامل

Fast distance-driven projection and truncation management for iterative cone-beam CT reconstruction

The purpose of this study was to improve the speed of the Simultaneous Algebraic Reconstruction Technique (SART) for truncated cone-beam (CB) projections using a distance-driven forward projector. First, we optimized the innermost loop of the projector for a cone-beam scanner with a circular source trajectory and a flat-panel imager. We showed that the innermost loop of the distance-driven proj...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001