Comparison of traditional and plethysmographic methods for measuring pulsus paradoxus.

نویسندگان

  • Jeff A Clark
  • Mary Lieh-Lai
  • Ron Thomas
  • Kalyani Raghavan
  • Ashok P Sarnaik
چکیده

BACKGROUND In the evaluation of patients with acute asthma, pulsus paradoxus (PP) is an objective and noninvasive indicator of the severity of airway obstruction. However, in children PP may be difficult or impossible to measure. Indwelling arterial catheters facilitate the measurement of PP, but they are invasive and generally reserved for critically ill patients. OBJECTIVE To determine the utility of the plethysmographic waveform (PPpleth) of the pulse oximeter in measuring PP. METHODS Patients from the pediatric intensive care unit, emergency department, and inpatient wards of a tertiary care pediatric hospital were eligible for the study. A total of 36 patients (mean age [SD], 11.2 [4.7] years) were enrolled in the study. Pulsus paradoxus was measured using the traditional auscultatory (PPausc) method with a sphygmomanometer. Pulsus paradoxus was then measured using a blood pressure cuff observing for the disappearance and reappearance of the (PPpleth) on the pulse oximeter. Mean difference and 95% confidence intervals were calculated for each method. The 2 methods were also analyzed for correlation and agreement using the Pearson product moment correlation and a Bland and Altman plot. RESULTS Patients with status asthmaticus had higher PPausc and PPpleth readings compared with nonasthmatic patients. Pulsus paradoxus measured by plethysmography in patients with and without asthma was similar to PPausc readings (mean difference, 0.6 mm Hg; 95% confidence interval, -0.6 to 2.1 mm Hg). Individual PPpleth readings showed significant correlation and agreement with PPausc readings in patients both with and without asthma. CONCLUSION Measurement of PP using the pulse oximeter-pulse plethysmographic waveform offers a simple and noninvasive method for evaluating patients with airway obstruction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pulsus paradoxus.

Systolic blood pressure normally falls during quiet inspiration in normal individuals. Pulsus paradoxus is defined as a fall of systolic blood pressure of >10 mmHg during the inspiratory phase. Pulsus paradoxus can be observed in cardiac tamponade and in conditions where intrathoracic pressure swings are exaggerated or the right ventricle is distended, such as severe acute asthma or exacerbatio...

متن کامل

Mechanism of pulsus paradoxus in clinical shock.

An inspiratory fall in systolic arterial pressure of more than 10 mm Hg (pulsus paradoxus) was noted in 30 of 61 patients with shock. Inspiratory right atrial pressures and total blood volumes were significantly lower in patients with pulsus paradoxus. Rapid infusion of dextran in 22 patients usually was effective in reversing the exaggerated inspiratory fall in systolic pressure. Total periphe...

متن کامل

Pulsus paradoxus in ventilated and non-ventilated patients.

Human physiology changes are often amplified in disease states and may be altered when a patient is mechanically ventilated. Normally, systolic blood pressure is slightly lower during inspiration than expiration due to the change in intrathoracic pressure. Pulsus paradoxus is a phenomenon in which the difference in systolic blood pressure (BP) between inspiration and expiration is more than 10 ...

متن کامل

Pulsus paradoxus in a patient with tricuspid atresia and hypoplastic right heart.

Increased inspiratory right ventricular filling with a consequent shift of the ventricular septum to the left, thereby decreasing left ventricular filling, has been suggested as a mechanism of pulsus paradoxus. We recently saw a patient with tricuspid atresia and hypoplastic right ventricle who developed pulsus paradoxus. His course may help clarify the contribution of this mechanism.

متن کامل

Use of pulse oximetry to recognize severity of airflow obstruction in obstructive airway disease: correlation with pulsus paradoxus.

STUDY OBJECTIVES The purpose of this cross-sectional study was to confirm the observation that pulse oximetry tracing correlates with pulsus paradoxus, and is therefore a measure of the severity of air trapping in obstructive airway disease. DESIGN Cross-sectional survey. SETTING The ICU in a tertiary care academic hospital. PATIENTS Twenty-six patients consecutively admitted to the ICU w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of pediatrics & adolescent medicine

دوره 158 1  شماره 

صفحات  -

تاریخ انتشار 2004