Automated resolution of chromatographic signals by independent component analysis-orthogonal signal deconvolution in comprehensive gas chromatography/mass spectrometry-based metabolomics

نویسندگان

  • Xavier Domingo-Almenara
  • Alexandre Perera-Lluna
  • Noelia Ramírez
  • Jesús Brezmes
چکیده

Comprehensive gas chromatography-mass spectrometry (GC×GC-MS) provides a different perspective in metabolomics profiling of samples. However, algorithms for GC×GC-MS data processing are needed in order to automatically process the data and extract the purest information about the compounds appearing in complex biological samples. This study shows the capability of independent component analysis-orthogonal signal deconvolution (ICA-OSD), an algorithm based on blind source separation and distributed in an R package called osd, to extract the spectra of the compounds appearing in GC×GC-MS chromatograms in an automated manner. We studied the performance of ICA-OSD by the quantification of 38 metabolites through a set of 20 Jurkat cell samples analyzed by GC×GC-MS. The quantification by ICA-OSD was compared with a supervised quantification by selective ions, and most of the R(2) coefficients of determination were in good agreement (R(2)>0.90) while up to 24 cases exhibited an excellent linear relation (R(2)>0.95). We concluded that ICA-OSD can be used to resolve co-eluted compounds in GC×GC-MS.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monolithic silica-based capillary reversed-phase liquid chromatography/electrospray mass spectrometry for plant metabolomics.

Application of C18 monolithic silica capillary columns in HPLC coupled to ion trap mass spectrometry detection was studied for probing the metabolome of the model plant Arabidopsis thaliana. It could be shown that the use of a long capillary column is an easy and effective approach to reduce ionization suppression by enhanced chromatographic resolution. Several hundred peaks could be detected u...

متن کامل

Spectral Deconvolution for Gas Chromatography Mass Spectrometry-Based Metabolomics: Current Status and Future Perspectives

Mass spectrometry coupled to gas chromatography (GC-MS) has been widely applied in the field of metabolomics. Success of this application has benefited greatly from computational workflows that process the complex raw mass spectrometry data and extract the qualitative and quantitative information of metabolites. Among the computational algorithms within a workflow, deconvolution is critical sin...

متن کامل

Analysis of gin essential oil mixtures by multidimensional and one-dimensional gas chromatography/mass spectrometry with spectral deconvolution.

The composition of essential oils and their mixtures used to formulate gin is usually too complex to separate all sample components by standard capillary gas chromatography (GC). In particular, minor constituents that possess important organoleptic properties can be masked by co-elution with major sample components. A solution is provided that combines gas chromatography/mass spectrometry (GC/M...

متن کامل

Instrument and process independent binning and baseline correction methods for liquid chromatography-high resolution-mass spectrometry deconvolution.

Setting appropriate bin sizes to aggregate hyphenated high-resolution mass spectrometry data, belonging to similar mass over charge (m/z) channels, is vital to metabolite quantification and further identification. In a high-resolution mass spectrometer when mass accuracy (ppm) varies as a function of molecular mass, which usually is the case while reading m/z from low to high values, it becomes...

متن کامل

Computational Analyses of Spectral Trees from Electrospray Multi-Stage Mass Spectrometry to Aid Metabolite Identification

Mass spectrometry coupled with chromatography has become the major technical platform in metabolomics. Aided by peak detection algorithms, the detected signals are characterized by mass-over-charge ratio (m/z) and retention time. Chemical identities often remain elusive for the majority of the signals. Multi-stage mass spectrometry based on electrospray ionization (ESI) allows collision-induced...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Computer methods and programs in biomedicine

دوره 130  شماره 

صفحات  -

تاریخ انتشار 2016