Quantification of Calcium Amount in a New Experimental Model: A Comparison between Ultrasound and Computed Tomography.
نویسندگان
چکیده
PURPOSE Calcification is an important prognostic factor in aortic valve stenosis. However, there is no ultrasound (US) method available to accurately quantify calcification in this setting to date. We aimed to validate a new US method for measuring the amount of calcium in an in vitro model, and compare it to computed tomography (CT), the current imaging gold standard. MATERIALS AND METHODS An agar phantom (2% agar) was made, containing 9 different amounts of calcium-hydroxyapatite Ca5(PO4)3OH (2 to 50 mg). The phantoms were imaged with micro-CT and US (10 MHz probe). The calcium area (areacalcium) and its maximum pixel value (PVmax) were obtained. These values were summed to calculate CT and US calcium scores (∑(areacalcium × PVmax)) and volumes (∑areacalcium). Both US- and CT-calcium scores were compared with the calcium amounts, and with each other. RESULTS Both calcium scores correlated significantly with the calcium amount (R2 = 0.9788, p<0.0001 and R2 = 0.8154, p<0.0001 for CT and US respectively). Furthermore, there was a significant correlation between US and CT for calcium volumes (R2 = 0.7392, p<0.0001) and scores (R2 = 0.7391, p<0.0001). CONCLUSION We developed a new US method that accurately quantifies the amount of calcium in an in vitro model. Moreover it is strongly correlated with CT.
منابع مشابه
Comparison of central composite design and artificial neural network approaches for modeling and optimization of 2-methylpropane-2-thiol removal from contaminated soil by ultrasound
In this article a comparative study for modeling and optimization of 2-methylpropane-2-thiol removal from contaminated soil by ultrasound is investigated. Central Composite Design (CCD) and artificial neural network (ANN) were utilized and compared to each other in order to obtain appropriate predicting model with respect to sonication power (w), sonication time (min) and water/reactor volume r...
متن کاملComparison of Diagnostic Accuracy of Cone Beam Computed Tomography and Digital Radiography for Detection of Vertical Root Fractures with and without Gutta Percha
Objective: Diagnosis of vertical root fractures (VRFs) is critical in endodontics which most of the times occurs in endodontically treated teeth with root canal fillings such as gutta percha. Despite Cone Beam Computed Tomography (CBCT) has significantly enhanced image quality compared to digital radiography (DR) which aid the diagnosis, artifacts has remained as a problem in VRF detection . ...
متن کاملCoronary Artery Calcium Quantification in Contrast-enhanced Computed Tomography Angiography
Coronary arteries are the blood vessels supplying oxygen-rich blood to the heart muscles. Coronary artery calcium (CAC), which is the total amount of calcium deposited in these arteries, indicates the presence or the future risk of coronary artery diseases. Quantification of CAC is done by using computed tomography (CT) scan which uses attenuation of xray by different tissues in the body to gen...
متن کاملمقایسه دقت توموگرافی سهبعدی با اشعه مخروطی با توموگرافی کامپیوتری مرسوم در تشخیص بیماریهای سینوس پارانازال
Background: Paranasal sinus disease is one of the most common problems of patients that refer to ENT centers. Adding to clinical examination imaging plays an important role in diagnosis and treatment. Also the imaging of paranasal sinuses is necessary before surgery. Although computed tomography is the modality of choice for these areas, it has some disadvantages which the most important one is...
متن کاملAssessment of X-Ray Crosstalk in a Computed Tomography Scanner with Small Detector Elements Using Monte Carlo Method
Introduction: Crosstalk is a leakage of X-ray or light produced in a matrix of X-ray detectors or array of photodiodes in one element to other elements affecting on image contrast and spatial resolution. In this study, we assessed X-ray crosstalk in a computed tomography (CT) scanner with small detector elements to estimate the effect of various parameters such as X-ray tube voltage, detector e...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- PloS one
دوره 11 2 شماره
صفحات -
تاریخ انتشار 2016