False-positive oral fluid rapid HIV tests--New York City, 2005-2008.
ثبت نشده
چکیده
The New York City Department of Health and Mental Hygiene (NYC DOHMH) operates 10 sexually transmitted disease (STD) walk-in clinics offering various free services, including confidential or anonymous testing for human immunodeficiency virus (HIV). In January 2004, the STD clinics introduced on-site rapid HIV testing of finger-stick whole-blood specimens using the OraQuick(R) brand test (OraSure Technologies, Bethlehem, Pennsylvania). In March 2005, the clinics replaced finger-stick whole-blood testing with oral fluid testing with the OraQuick Advance Rapid HIV-1/2 Antibody Test. The clinics use Western blot confirmatory tests on serum to confirm all whole-blood or oral fluid reactive (i.e., preliminary positive) rapid tests. In late 2005, an unexpected increase in the number of false-positive oral fluid tests occurred, but the increase subsided after several months. In December 2005, while the cluster of false-positive oral fluid test results was being investigated, the NYC DOHMH Bureau of STD Control suspended oral fluid testing in the clinics for 3 weeks and replaced it with finger-stick whole-blood rapid testing, which produced no false-positive test results. On December 21, 2005, NYC DOHMH resumed oral fluid rapid testing but also introduced the use of immediate follow-up finger-stick whole-blood testing, using a second OraQuick test, after any reactive oral fluid test result. In late 2007, another larger increase in the incidence of false-positive oral fluid rapid test results was observed. The cause for the episodic increases in false-positive oral fluid tests has not yet been determined. NYC DOHMH has again suspended the use of oral fluid testing in STD clinics, and finger-stick whole-blood testing is the only rapid HIV test being used in this setting. These findings underscore the importance of confirming all reactive HIV tests, both from oral fluid and whole-blood specimens. In addition, the results suggest that the NYC DOHMH strategy of following up reactive oral fluid test results with an immediate finger-stick whole-blood test reduced the number of apparent false-positive oral fluid test results and might be a useful strategy in other settings and locations.
منابع مشابه
Investigation of False Positive Results with an Oral Fluid Rapid HIV-1/2 Antibody Test
BACKGROUND In March 2004, the OraQuick rapid HIV antibody test became the first rapid HIV test approved by the US Food and Drug Administration for use on oral fluid specimens. Test results are available in 20 minutes, and the oral fluid test is non-invasive. From August 2004-June 2005, we investigated a sudden increase in false-positive results occurring in a performance study of OraQuick oral-...
متن کاملMonitoring Temporal Changes in the Specificity of an Oral HIV Test: A Novel Application for Use in Postmarketing Surveillance
BACKGROUND Postmarketing surveillance is routinely conducted to monitor performance of pharmaceuticals and testing devices in the marketplace. However, these surveillance methods are often done retrospectively and, as a result, are not designed to detect issues with performance in real-time. METHODS AND FINDINGS Using HIV antibody screening test data from New York City STD clinics, we develop...
متن کاملRepeat Confirmatory Testing for Persons with Discordant Whole Blood and Oral Fluid Rapid HIV Test Results: Findings from Post Marketing Surveillance
BACKGROUND Reactive oral fluid and whole blood rapid HIV tests must be followed with a confirmatory test (Western blot (WB), immunofluorescent assay (IFA) or approved nucleic acid amplification test (NAAT)). When the confirmatory result is negative or indeterminate (i.e. discordant with rapid result), repeat confirmatory testing should be conducted using a follow-up specimen. Previous reports h...
متن کاملHIV false positive results and Flu vaccination
Abstract False positive results are the major problem influencing interpretation of Clinical Laboratory test. They are originated mostly in the other diseases, technical errors and the recent vaccination. The problem has been presented since 1991 is positive HIV test after influenza Vaccination (1). The False positive has been reported in Cases using Eliza, one of The most common test to screen...
متن کاملImpact of Round-the-Clock, Rapid Oral Fluid HIV Testing of Women in Labor in Rural India
BACKGROUND Testing pregnant women for HIV at the time of labor and delivery is the last opportunity for prevention of mother-to-child HIV transmission (PMTCT) measures, particularly in settings where women do not receive adequate antenatal care. However, HIV testing and counseling of pregnant women in labor is a challenge, especially in resource-constrained settings. In India, many rural women ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- MMWR. Morbidity and mortality weekly report
دوره 57 24 شماره
صفحات -
تاریخ انتشار 2008