Double-blind, prospective, randomized study of warmed, humidified carbon dioxide insufflation vs standard carbon dioxide for patients undergoing laparoscopic cholecystectomy.

نویسندگان

  • David R Farley
  • Susan M Greenlee
  • Dirk R Larson
  • Jeffrey R Harrington
چکیده

HYPOTHESIS Patients undergoing warmed, humidified carbon dioxide (CO2) insufflation for laparoscopic cholecystectomy will (1) maintain a warmer intraoperative core temperature, (2) have their surgeon experience less fogging of the camera lens, and (3) have less postoperative pain than patients undergoing laparoscopic cholecystectomy with standard CO2 insufflation. DESIGN A double-blind, prospective, randomized study comparing patients undergoing laparoscopic cholecystectomy with standard CO2 insufflation vs those receiving warmed, humidified CO2 (Insuflow Filter Heater Hydrator; Lexion Medical, St Paul, Minn) was performed. Main variables included patient core temperature, postoperative pain, analgesic requirements, and camera lens fogging. RESULTS One hundred one blinded patients (69 women, 32 men) undergoing laparoscopic cholecystectomy were randomized into 2 groups-52 receiving standard CO2 insufflation (group A) and 49 receiving warmed, humidified CO2 (group B). Mean patient intraoperative core temperature change (group A decreased by 0.03 degrees C, group B increased by 0.29 degrees C, P =.01) and mean abdominal pain (Likert scale, 0-10) at 14 days postoperatively (group A, 1.0; group B, 0.3; P =.02) were different. Other variables (camera lens fogging, early postoperative pain, narcotic requirements, recovery room stay, and return to normal activities) between groups were similar. CONCLUSION While patients undergoing laparoscopic cholecystectomy with warmed, humidified CO2 had several advantages that were statistically significant, no major clinically relevant differences between groups A and B were evident.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of warm carbon dioxide insufflators does not affect intra-colonic gas temperature and has no effect on polyp detection rate during colonoscopy – a randomized controlled trial

BACKGROUND AND STUDY AIMS  Methods to improve polyp detection during colonoscopy have been investigated, with conflicting results for warm water irrigation. Carbon Dioxide (CO 2) warmed to 37 °C may have similar or more pronounced effects on bowel motility. This study aimed to assess whether warmed CO 2 would improve polyp detection compared to room temperature air insufflation. PATIENTS AND ...

متن کامل

Meta-analysis of the effect of warm humidified insufflation on pain after laparoscopy.

BACKGROUND Studies on the use of warmed and humidified insufflation (WHI) in laparoscopic abdominal procedures to reduce pain have been inconclusive owing to small sample sizes. METHODS An electronic database search identified all randomized controlled trials (RCTs) on adults undergoing elective laparoscopic abdominal surgery under general anaesthesia in which the exposure group had WHI and t...

متن کامل

Improved Outcomes for Lap-Banding Using the Insuflow® Device Compared with Heated-Only Gas

BACKGROUND AND OBJECTIVES Preconditioning gas by humidification and warming the pneumoperitoneum improves laparoscopic outcomes. This prevents peritoneal desiccation and detrimental events related to traditional cold-dry gas. Few comparisons have been done comparing traditional cold-dry, heated-only, and humidified-warmed carbon dioxide. METHODS A prospective, controlled, randomized, double-b...

متن کامل

Warmed, humidified CO2 insufflation benefits intraoperative core temperature during laparoscopic surgery: A meta‐analysis

BACKGROUND Intraoperative hypothermia is linked to postoperative adverse events. The use of warmed, humidified CO2 to establish pneumoperitoneum during laparoscopy has been associated with reduced incidence of intraoperative hypothermia. However, the small number and variable quality of published studies have caused uncertainty about the potential benefit of this therapy. This meta-analysis was...

متن کامل

Transoesophageal echocardiographic assessment of haemodynamic function during laparoscopic cholecystectomy.

We have measured cardiovascular changes associated with insufflation of carbon dioxide and the reverse Trendelenburg position during laparoscopic cholecystectomy, using transoesophageal echocardiography in 13 healthy patients. End-tidal carbon dioxide values increased after insufflation of carbon dioxide, with values significantly (P < 0.05) increased after lateral tilt positioning. Creation of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Archives of surgery

دوره 139 7  شماره 

صفحات  -

تاریخ انتشار 2004