The feasibility of recording event-related potentials (ERP) during functional MRI (fMRI) scanning was studied. Using an alternating checkerboard stimulus in a blocked presentation, visually evoked potentials were obtained with their expected configuration and latencies. A clustered echoplanar imaging protocol was applied to observe the hemodynamic response due to the visual stimulus interleaved with measuring ERPs. Influences of the electrode/amplifier set up on MRI scanning and the scanning process on the recording of electrophysiological signals are reported and discussed. Artifacts overlaid on the electrophysiological recordings were corrected by post hoc filtering methods presented here. Implications and limitations of conducting combined ERP/fMRI experiments using higher-level cognitive stimuli are discussed. Magn Reson Med 44:277-282, 2000.
منابع مشابه
Combined measurement of event-related potentials (ERPs) and fMRI.
The study investigates the possibility of combined recording event-related potentials (ERPs) and functional MRI (fMRI). Visual evoked potentials (VEPs) were elicited by an alternating black and white checkerboard, which was presented blockwise outside the static 1.5 T magnetic field and during an echo planar imaging (EPI). An fMRI sequence with a time window for interleaved EEG-measurement and ...
متن کاملSequential effects of propofol on functional brain activation induced by auditory language processing: an event-related functional magnetic resonance imaging study.
BACKGROUND We have investigated the effect of propofol on language processing using event-related functional magnetic resonance imaging (MRI). METHODS Twelve healthy male volunteers underwent MRI scanning at a magnetic field strength of 3 Tesla while performing an auditory language processing task. Functional images were acquired from the perisylvian cortical regions that are associated with ...
متن کاملArtifacts in 3-Tesla MRI: Physics and reduction strategies
Magnetic resonance imaging (MRI) at a field strength of 3 Tesla has become more and more frequently used in recent years. In an increasing number of radiological sites, 3-Tesla MRI now starts to play the same role for clinical imaging that was occupied by 1.5-Tesla systems in the past. Because of physical limitations related to the higher field strength and because of protocols transferred from...
متن کاملOccupational exposure of healthcare and research staff to static magnetic stray fields from 1.5–7 Tesla MRI scanners is associated with reporting of transient symptoms
OBJECTIVES Limited data is available about incidence of acute transient symptoms associated with occupational exposure to static magnetic stray fields from MRI scanners. We aimed to assess the incidence of these symptoms among healthcare and research staff working with MRI scanners, and their association with static magnetic field exposure. METHODS We performed an observational study among 36...
متن کاملSingle-trial analysis of oddball event-related potentials in simultaneous EEG-fMRI.
There has recently been a growing interest in the use of simultaneous electroencephalography (EEG) and functional MRI (fMRI) for evoked activity in cognitive paradigms, thereby obtaining functional datasets with both high spatial and temporal resolution. The simultaneous recording permits obtaining event-related potentials (ERPs) and MR images in the same environment, conditions of stimulation,...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Magnetic resonance in medicine
دوره 44 2 شماره
صفحات -
تاریخ انتشار 2000