Integrated Myocardial Perfusion Imaging Diagnostics Improve Detection of Functionally Significant Coronary Artery Stenosis by 13N-ammonia Positron Emission Tomography.

نویسندگان

  • Joo Myung Lee
  • Chee Hae Kim
  • Bon-Kwon Koo
  • Doyeon Hwang
  • Jonghanne Park
  • Jinlong Zhang
  • Yaliang Tong
  • Ki-Hyun Jeon
  • Ji-In Bang
  • Minseok Suh
  • Jin Chul Paeng
  • Gi Jeong Cheon
  • Sang-Hoon Na
  • Jung-Min Ahn
  • Seung-Jung Park
  • Hyo-Soo Kim
چکیده

BACKGROUND Recent evidence suggests that the diagnostic accuracy of myocardial perfusion imaging is improved by quantifying stress myocardial blood flow (MBF) in absolute terms. We evaluated a comprehensive quantitative (13)N-ammonia positron emission tomography ((13)NH3-PET) diagnostic panel, including stress MBF, coronary flow reserve (CFR), and relative flow reserve (RFR) in conjunction with relative perfusion defect (PD) assessments to better detect functionally significant coronary artery stenosis. METHODS AND RESULTS A total of 130 patients (307 vessels) with coronary artery disease underwent both (13)NH3-PET and invasive coronary angiography with fractional flow reserve (FFR) measurement. Diagnostic accuracy, optimal cut points, and discrimination indices of respective (13)NH3-PET quantitative measures were compared, with FFR as standard reference. The capacity to discern disease with stepwise addition of stress MBF, CFR, and RFR to qualitatively assessed relative PD was also gauged, using the category-free net reclassification index. All quantitative measures showed significant correlation with FFR (PET-derived CFR, r=0.388; stress MBF, r=0.496; and RFR, r=0.780; all P<0.001). Optimal respective cut points for FFR ≤0.8 and ≤0.75 were 1.99 and 1.84 mL/min per g for stress MBF and 2.12 and 2.00 for PET-derived CFR. Discrimination indices of quantitative measures that correlated with FFR ≤0.8 were all significantly higher than that of relative PD (area under the curve: 0.626, 0.730, 0.806, and 0.897 for relative PD, CFR, stress MBF, and RFR, respectively; overall comparison P<0.001). The capacity for functionally significant coronary stenosis was incrementally improved by the successive addition of CFR (net reclassification index=0.629), stress MBF (net reclassification index=0.950), and RFR (net reclassification index=1.253; all P<0.001) to relative PD. CONCLUSIONS Integrating quantitative (13)NH3-PET measures with qualitative myocardial perfusion assessment provides superior diagnostic accuracy and improves the capacity to detect functionally significant coronary artery stenosis. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifiers: NCT01621438 and NCT01366404.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

13N ammonia myocardial imaging at rest and with exercise in normal volunteers. Quantification of absolute myocardial perfusion with dynamic positron emission tomography.

Positron emission tomography (PET) was applied to the measurement of myocardial perfusion using the perfusion tracer 13N-labeled ammonia. 13N ammonia was delivered intravenously to 13 healthy volunteers both at rest and during supine bicycle exercise. Dynamic PET imaging was obtained in three cross-sectional planes for 10 minutes commencing with each injection. The left ventricle was divided in...

متن کامل

13N-ammonia myocardial blood flow and uptake: relation to functional outcome of asynergic regions after revascularization.

OBJECTIVES In this study we determined whether 13N-ammonia uptake measured late after injection provides additional insight into myocardial viability beyond its value as a myocardial blood flow tracer. BACKGROUND Myocardial accumulation of 13N-ammonia is dependent on both regional blood flow and metabolic trapping. METHODS Twenty-six patients with chronic coronary artery disease and left ve...

متن کامل

Positron Emission Tomography-Determined Hyperemic Flow, Myocardial Flow Reserve, and Flow Gradient—Quo Vadis?

Positron emission tomography/computed tomography (PET/CT) applied with positron-emitting flow tracers such as 13N-ammonia and 82Rubidium enables the quantification of both myocardial perfusion and myocardial blood flow (MBF) in milliliters per gram per minute for coronary artery disease (CAD) detection and characterization. The detection of a regional myocardial perfusion defect during vasomoto...

متن کامل

Quantification of Absolute Myocardial Perfusion With Dynamic Positron Emission Tomography

Positron emission tomography (PET) was applied to the measurement of myocardial perfusion using the perfusion tracer 13N-labeled ammonia. 13N ammonia was delivered intravenously to 13 healthy volunteers both at rest and during supine bicycle exercise. Dynamic PET imaging was obtained in three cross-sectional planes for 10 minutes commencing with each injection. The left ventricle was divided in...

متن کامل

Phase II Safety and Clinical Comparison With Single-Photon Emission Computed Tomography Myocardial Perfusion Imaging for Detection of Coronary Artery Disease

Objectives This was a phase II trial to assess flurpiridaz F 18 for safety and compare its diagnostic performance for positron emission tomography (PET) myocardial perfusion imaging (MPI) with Tc-99m single-photon emission computed tomography (SPECT) MPI with regard to image quality, interpretative certainty, defect magnitude, and detection of coronary artery disease (CAD) ( 50% stenosis) on in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Cardiovascular imaging

دوره 9 9  شماره 

صفحات  -

تاریخ انتشار 2016