Guiding and Optimization of Resynchronization Therapy with Dynamic Three-dimensional Echocardiography and Semi-automated Border Detection: a Feasibility Study
نویسندگان
چکیده
W e have used for this implant, 5 leads from 2 different producers: 2187 (16 pts), 4189 (18 pts), 4191 (25 pts) and 4193 (15 pts) from Medtronic and 4512 (48 pts) from Guidmt. As a parameter of better handl ing we have considered a reduced fluoro-time for the positioning of the LV lead. W e have made comparison in fluoro-time for each lead and dividing the 5 leads in two group: stylet-guided leads (4189 and 2187) and angioplasty-wire guided leads (4191,4193 and 4512). W e have not found any significant differences in fluoro-time nor for any of the considered leads neither for each group of leads. W e have also analysed if fluoro-time was related to single operator experience or to Centre experience. W e have found out that the longer the patient follow-up the longer the fluoro-time and the greater the number of patients implanted by the single operator the shorter the fluoro-time. In conclusion, OUT data seem to demonstrate that all the leads available on the market have the same good handl ing and that-once the operator has gained a good experience in such an intervention the mean fluoro-time required to position all the leads could be reduced to acceptable values.
منابع مشابه
Dynamic three-dimensional echocardiography combined with semi-automated border detection offers advantages for assessment of resynchronization therapy
Simultaneous electrical stimulation of both ventricles in patients with interventricular conduction disturbance and advanced heart failure improves hemodynamics and results in increased exercise tolerance, quality of life. We have developed a novel technique for the assessment and optimization of resynchronization therapy. Our approach is based on transthoracic dynamic three-dimensional (3D) ec...
متن کاملFeasibility and initial experience of assessment of mechanical dyssynchrony using cardiovascular magnetic resonance and semi-automatic border detection
BACKGROUND The systolic dyssynchrony index (SDI) has been introduced as a measure of mechanical dyssynchrony using three-dimensional echocardiography to select patients who may benefit from cardiac resynchronization therapy (CRT). However, three-dimensional echocardiography may be inadequate in a number of patients with suboptimal acoustic window and no single echocardiographic measure of dyssy...
متن کاملA New Algorithm for Skin Lesion Border Detection in Dermoscopy Images
Background: With advances in medical imaging systems, digital dermoscopy has become one of the major imaging modalities in the analysis of skin lesions. Thus, automated segmentation or border detection has a great impact on the subsequent steps of skin cancer computer-aided diagnosis using demoscopy images. Since dermoscopy images suffer from artifacts such as shading and hair, there is a need ...
متن کاملEvaluation of automated contour detection to produce regional delay maps from high temporal resolution cine images in patients undergoing CRT
Background Recently, high temporal resolution short-axis cine images have been used to create left ventricular (LV) regional mechanical delay (RMD) maps in patients undergoing cardiac resynchronization therapy (CRT). Generating the endocardial segmentation required for RMD analysis is both time-consuming and subjective. A semi-automated segmentation method for time-continuous contour detection ...
متن کاملComparison of cardiovascular magnetic resonance with real-time three-dimensional echocardiography and the right ventricular automated systolic index in the assessment of the right ventricular function
Background The right ventricular (RV) function has an important diagnostic value in many cardiopulmonary diseases and is a predictor for the long-term outcome. Cardiovascular magnetic resonance (CMR) is the gold-standard for the RV quantification as the complex anatomy of the RV, i.e. its crescentic shape, impedes reliable measurement by two-dimensional echocardiography (EC). Yet, CMR or real-t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2004