New Validated Potentiometric Determination of Vasodilator Pentoxifylline in its Pharmaceutical Formulations and Biological Fluids

نویسنده

  • Nawal Alarfaj
چکیده

The construction and performance characteristics of pentoxifylline selective electrodes were developed. Two types of electrodes: plastic membrane I and coated wire II were constructed based on the incorporation of pentoxifylline with phosphotungstic acid (PTA). The influence of membrane composition, kind of plasticizer, pH of the test solution, soaking time, and foreign ions on the electrodes was investigated. The electrodes showed a Nernstain response with a mean calibration graph slope of 56.77 ± 0.19 and 55.76 ± 0.71 mV decade at 25 oC for electrode I and II respectively, over pentoxifylline concentration range from 1.0 10-1.0 10 and 9.0 10-1.0 10 mol L, with detection limits 4.89 10 and 3.90 10 mol L for electrode I and II, respectively. The pH range of the constructed electrodes was 4-6. Interferences from common cations, alkaloids, sugars, amino acids and drug excipients were reported. The results obtained by the proposed electrodes were also applied successfully to the determination of the drug in its pharmaceutical preparations and biological fluids.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Adaptive neuro-fuzzy inference system (ANFIS) applied for spectrophotometric determination of fluoxetine and sertraline in pharmaceutical formulations and biological fluid

The UV-spectrophotometric method of analysis was proposed for simultaneous determination of fluoxetine (FLX) and sertraline (SRT). Considering the strong spectral overlap between UV-Vis spectra of these compounds, a previous separation should be carried out in order to determine them by conventional spectrophotometric techniques. Here, full-spectrum multivariate calibrations adaptive neuro-fuzz...

متن کامل

Development of novel potentiometric sensors for determination of lidocaine hydrochloride in pharmaceutical preparations, serum and urine samples

This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations. It was based on potentiometric titration of lidocaine hydrochloride using modified ...

متن کامل

Development of novel potentiometric sensors for determination of lidocaine hydrochloride in pharmaceutical preparations, serum and urine samples

This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations. It was based on potentiometric titration of lidocaine hydrochloride using modified ...

متن کامل

New Coated Wire Sensors for Potentiometric Determination of Gemifloxacin in Pure Form, Pharmaceutical Formulations and Biological Fluids

A simple, accurate and precise potentiometric method was developed for the determination of gemifloxacin mesylate (GFX). Three ion selective coated wire sensors have been constructed from the incorporation of (GFX) with the ion-pairing agents phosphotungstic acid (PTA), phosphomolybdic acid (PMA) and Ammonium reineckate salt (ARS). The three sensors show nearly Nernestian response over the conc...

متن کامل

Ofloxacin determination in urine, serum and pharmaceuticals using an automatic flow potentiometric system.

An automatic system was developed to determine ofloxacin in biological fluids and pharmaceutical formulations. Drug detection was carried out by a potentiometric membrane sensor based on [bis(trifluoromethyl)phenyl]borate as molecular-recognition material. The tubular shaped detector system was solidly attached to the manifold, creating a high-throughput stable setup (50 samples per hour) appro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011