Influence of crown-to-implant ratio on periimplant marginal bone loss in the posterior region: a five-year retrospective study

نویسندگان

  • Kyung-Jin Lee
  • Yong-Gun Kim
  • Jin-Woo Park
  • Jae-Mok Lee
  • Jo-Young Suh
چکیده

PURPOSE The aim of this study was to evaluate the influence of the crown-to-implant (C/I) ratio on the change in marginal bone level around the implant and to determine the site-related factors influencing the relationship between the C/I ratio and periimplant marginal bone loss. METHODS A total of 259 implants from 175 patients were evaluated at a mean follow-up of five years. Implants were divided into two groups according to their C/I ratios: ≤1, and >1. Site-related factors having an influence on the relationship between C/I ratio and periimplant marginal bone loss were analyzed according to the implant location, implant diameter, implant manufacturer, prosthesis type, and guided bone regeneration (GBR) procedure. RESULTS It was found that 1) implants with a C/I ratio below 1 exhibited greater periimplant marginal bone loss than implants with a C/I ratio more than 1, 2) site-related factors had an effect on periimplant marginal bone loss, except for the implant system used, 3) the C/I ratio was the factor having more dominant influence on periimplant marginal bone loss, compared with implant diameter, prosthesis type, implant location, and GBR procedure, 4) implants with a C/I ratio below 1 showed greater periimplant marginal bone loss than implants with a C/I ratio greater than 1 in the maxilla, but not in the mandible, 5) and periimplant marginal bone loss was more affected by the implant system than the C/I ratio. CONCLUSIONS Within the limitations of this study, implants with a higher C/I ratio exhibited less marginal bone loss than implants with a lower C/I ratio in the posterior regions. The C/I ratio was a more dominant factor affecting periimplant marginal bone loss in the maxilla than the mandible. Meanwhile, the implant system was a more dominant factor influencing periimplant marginal bone loss than the C/I ratio.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی مقایسه ای اثر نسبت تاج به ایمپلنت بر روی میزان تحلیل استخوان مارجینال اطراف ایمپلنت در نواحی خلفی ماگزیلا و مندیبل

Introduction & Objective: Due to the patients’ growing interest in the use of dental implants, medical staff should be completely aware of treatment success and prognostic factors to prevent failures. The purpose of this study was to evaluate the effect of different crown to implant ratio (C / I Ratio) in the posterior areas of the maxilla and mandible as one of the most important princip...

متن کامل

Retrospective study of short and extra-short implants placed in posterior regions: influence of crown-to-implant ratio on marginal bone loss.

AIM The aim of this study is to evaluate the influence of crown-to-implant (CI) ratio as well as other surgical, prosthetic and biomechanical variables on marginal bone loss (MBL) and on the survival rates of implant-supported prostheses in short implants (≤8.5 mm in length) placed in posterior areas of maxilla and mandible. MATERIAL & METHODS This was a retrospective study based on clinical ...

متن کامل

Radiographic Comparison of Crestal Bone Loss Around Two Implant Systems with Different Surface Roughness: A Retrospective Study

Background and Aim: This retrospective study aimed to investigate the effects of surface roughness and implant body design on the amount of crestal bone loss around implant. Materials and Methods: In this retrospective study, dental records of 87 patients who received 139 implants were evaluated. The ITI group received 63 implants with moderate roughness, while the DIO group received 76 implan...

متن کامل

Long-term outcomes of short dental implants supporting single crowns in posterior region: a clinical retrospective study of 5-10 years.

OBJECTIVE Aimed to evaluate the long-term clinical and radiographic outcomes of short implants supporting single crowns in the posterior regions. MATERIAL AND METHODS A retrospective study design was adopted. The clinical and radiographic data of 231 short implants (intra-bony length ≤8 mm) supporting single crowns in 168 patients, were collected after 5-10 (mean 7.22) years' follow-up. Impla...

متن کامل

The clinical effectiveness of screw type Implant “Nisastan system” in the posterior region of the mandible: A 2 year prospective study

The clinical effectiveness of screw type Implant “Nisastan system” in the posterior region of the mandible: A 2 year prospective study Dr. M. Rismanchian * - Dr. R. Birang ** * Assistant Professor of Fixed Prosthodontics Dept., Faculty of Dentistry, Isfahan University of Medical Sciences. ** Assistant Professor of Periodontics Dept., Faculty of Dentistry, Isfahan University of Medical Sciences....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 42  شماره 

صفحات  -

تاریخ انتشار 2012