Assessment of internal auditory canal tumors: a comparison of contrast-enhanced T1-weighted and steady-state T2-weighted gradient-echo MR imaging.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Although contrast-enhanced T1-weighted MR imaging is the standard of reference for diagnosing tumor in the cerebellopontine angle, high-resolution T2-weighted imaging may show more details of the seventh and eighth cranial nerve branches, resulting in more accurate tumor volume measurements. The purpose of this study was to compare two MR sequences for their ability to delineate internal auditory canal tumors. METHODS Twenty-seven ears in 21 patients with 16 confirmed schwannomas were studied with the 3D T2-weighted prototype segment-interleaved motion-compensated acquisition in steady state (SIMCAST) and the T1-weighted contrast-enhanced spoiled gradient-echo (SPGR) techniques. Twenty-eight axial sections were acquired using parameters of 17/3.3 (TR/TE), a 40 degrees flip angle, a 20 x 15-cm or 22 x 16-cm field of view (FOV), a 512 x 256 matrix, and a 0.4- or 1.2-mm section thickness for the SIMCAST technique, and 30/4.2, a 30 degrees flip angle, a 20 x 20-cm FOV, a 512 x 288 matrix, and a 1.5-mm section thickness for the SPGR technique. Tumor appearance and depiction of surrounding anatomy, including the cranial nerves, were evaluated. Tumor volumes were measured by manual tracing. RESULTS Both sequences clearly identified tumors that ranged in size from 0.06 to 3.0 cm3. Measurements on both sequences agreed, on average, within 14%. The information from both sequences was complementary. SIMCAST usually delineated the CSF spaces better, whereas SPGR more clearly showed the tumor/brain boundary. CONCLUSION SIMCAST and SPGR are suitable for tumor detection and volume measurements. SPGR has somewhat better contrast, but SIMCAST excels at depicting the surrounding anatomy and tumor involvement of the seventh and eighth cranial nerves.
منابع مشابه
Detection of acoustic schwannoma: use of constructive interference in the steady state three-dimensional MR.
PURPOSE To compare constructive interference in the steady state (CISS) three-dimensional Fourier transform (3DFT) MR imaging with contrast-enhanced T1-weighted spin-echo MR imaging for accuracy in detecting acoustic schwannoma. METHODS One hundred twenty-five consecutive patients with possible acoustic schwannoma were examined. The accuracy of CISS-3DFT MR imaging in detecting abnormalities ...
متن کاملQuantification of blood-brain-barrier permeability dysregulation and inflammatory activity in MS lesions by dynamic-contrast enhanced MR imaging
Objective: Measurement of blood-brain permeability dysfunction in active and chronic MS lesions with T1-weighted dynamic contrast-enhanced MRI to show variation in inflammatory activity Background: blood-brain-barrier perfusion characterization impaired in MS as some studies have shown recently buta comparison between perfusion parameters in contrast-enhanced and non-enhanced lesions not have ...
متن کاملDifferentiation of vestibular schwannomas from meningiomas of the internal auditory canal using perilymphatic signal evaluation on T2-weighted gradient-echo fast imaging employing steady state acquisition at 3T
Background: Our aim was to confirm the usefulness of the perilymphatic signal changes on T2-weighted (T2W) gradient-echo sequence to differentiate vestibular schwannomas from internal auditory canal (IAC) meningiomas, through a compartmental analysis of inner ear fluids signal intensity. Methods: A total of 203 patients with all criteria for typical vestibular schwannoma on T1-weighted contrast...
متن کاملFast multiplanar spoiled gradient-recalled imaging of the liver: pulse sequence optimization and comparison with spin-echo MR imaging.
OBJECTIVE The purpose of this study was to optimize a new rapid-acquisition MR pulse sequence, called fast multiplanar spoiled gradient-recalled (FMPSPGR) imaging, for breath-hold imaging of the liver and to compare unenhanced and contrast-enhanced FMPSPGR with standard spin-echo imaging in detecting liver tumors. MATERIALS AND METHODS The pulse sequence was optimized at 1.5 T with a healthy ...
متن کاملCharacterization of Focal Liver Lesions with Superparamagnetic Iron Oxide-Enhanced MR Imaging: Value of Distributional Phase T1-Weighted Imaging
OBJECTIVE To determine the potential value of distributional-phase T1-weighted ferumoxides-enhanced magnetic resonance (MR) imaging for tissue characterization of focal liver lesions. MATERIALS AND METHODS Ferumoxides-enhanced MR imaging was performed using a 1.5-T system in 46 patients referred for evaluation of known or suspected hepatic malignancies. Seventy-three focal liver lesions (30 h...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 20 7 شماره
صفحات -
تاریخ انتشار 1999