Evaluating the performance of time-gated live-cell microscopy with lanthanide probes.
نویسندگان
چکیده
Probes and biosensors that incorporate luminescent Tb(III) or Eu(III) complexes are promising for cellular imaging because time-gated microscopes can detect their long-lifetime (approximately milliseconds) emission without interference from short-lifetime (approximately nanoseconds) fluorescence background. Moreover, the discrete, narrow emission bands of Tb(III) complexes make them uniquely suited for multiplexed imaging applications because they can serve as Förster resonance energy transfer (FRET) donors to two or more differently colored acceptors. However, lanthanide complexes have low photon emission rates that can limit the image signal/noise ratio, which has a square-root dependence on photon counts. This work describes the performance of a wide-field, time-gated microscope with respect to its ability to image Tb(III) luminescence and Tb(III)-mediated FRET in cultured mammalian cells. The system employed a UV-emitting LED for low-power, pulsed excitation and an intensified CCD camera for gated detection. Exposure times of ∼1 s were needed to collect 5-25 photons per pixel from cells that contained micromolar concentrations of a Tb(III) complex. The observed photon counts matched those predicted by a theoretical model that incorporated the photophysical properties of the Tb(III) probe and the instrument's light-collection characteristics. Despite low photon counts, images of Tb(III)/green fluorescent protein FRET with a signal/noise ratio ≥ 7 were acquired, and a 90% change in the ratiometric FRET signal was measured. This study shows that the sensitivity and precision of lanthanide-based cellular microscopy can approach that of conventional FRET microscopy with fluorescent proteins. The results should encourage further development of lanthanide biosensors that can measure analyte concentration, enzyme activation, and protein-protein interactions in live cells.
منابع مشابه
Lanthanide-based luminescent probes for selective time-gated detection of hydrogen peroxide in water and in living cells.
Lanthanide-based luminescent probes TPR1 and TPR2 were developed for the detection of hydrogen peroxide (H(2)O(2)) in living systems. The chemoselective reaction of these boronate-protected probes with H(2)O(2) resulted in an enhanced lanthanide sensitization and a 6-fold increase in luminescent intensity. TPR2 was utilized to measure the endogenous production of H(2)O(2) in RAW 264.7 macrophag...
متن کاملTime-Gated Orthogonal Scanning Automated Microscopy (OSAM) for High-speed Cell Detection and Analysis
We report a new development of orthogonal scanning automated microscopy (OSAM) incorporating time-gated detection to locate rare-event organisms regardless of autofluorescent background. The necessity of using long-lifetime (hundreds of microseconds) luminescent biolabels for time-gated detection implies long integration (dwell) time, resulting in slow scan speed. However, here we achieve high ...
متن کاملLighting up cells with lanthanide self-assembled helicates.
Lanthanide bioprobes and bioconjugates are ideal luminescent stains in view of their low propensity to photobleaching, sharp emission lines and long excited state lifetimes permitting time-resolved detection for enhanced sensitivity. We show here how the interplay between physical, chemical and biochemical properties allied to microfluidics engineering leads to self-assembled dinuclear lanthani...
متن کاملLive cell imaging of lysosomal pH changes with pH responsive ratiometric lanthanide probes.
Europium and terbium complexes of two structurally related ligands have been evaluated as optical probes to monitor changes in lysosomal pH; calibration using ionophores and fluorescent probes allows monitoring of the time dependence of lysosomal pH change, examining the green/red intensity ratio from internalised Tb-Eu complexes.
متن کاملTime gating improves sensitivity in energy transfer assays with terbium chelate/dark quencher oligonucleotide probes.
Lanthanides are attractive as biolabels because their long luminescence decay rates allow time-gated detection, which separates background scattering and fluorescence from the lanthanide emission. A stable and highly luminescent terbium complex based on a tetraisophthalamide (TIAM) chelate is paired with a polyaromatic-azo dark quencher (referred to as a Black Hole Quencher or BHQ) to prepare a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Biophysical journal
دوره 109 2 شماره
صفحات -
تاریخ انتشار 2015