A standard clinical instrument interface for robotic applications.
نویسندگان
چکیده
Many clinical laboratory instruments are not designed for robotic compatibility, hence the need for standardization of data communications and analyzer interface hardware. We developed an interface with supporting software that simplifies communication between a microcomputer and clinical instruments. Our interface establishes a standardized bidirectional communications protocol, which is useful in many clinical laboratory robotic projects. Instruments targeted for interfacing require no prior on-board communications capabilities. Additionally, modifications to the clinical instrument are minimized. Once installed, the interface translates input commands to codes or actions recognizable by the analyzer. Features not normally available to the user, such as electrode real-time response and full instrument status, are also reported by the interface, thereby establishing a remote monitor and control mechanism for the interfaced instrument. We have written an operating system to control the interface microcomputer, which in turn commands and monitors the clinical analyzer. A host computer controls the information flow to the interface and provides (a) requests to the interface for instrument operation and status and (b) commands to the interface to initiate the desired instrument operation. This arrangement maintains complete instrument functionality as designed by the manufacturer while allowing remote monitoring and operation of the instrument.
منابع مشابه
Control of a 2-DoF robotic arm using a P300-based brain-computer interface
In this study, a novel control algorithm, based on a P300-based brain-computer interface (BCI) is fully developed to control a 2-DoF robotic arm. Eight subjects including 5 men and 3 women perform a 2-dimensional target tracking in a simulated environment. Their EEG (Electroencephalography) signals from visual cortex are recorded and P300 components are extracted and evaluated to perform a real...
متن کاملComment: Applications of robotics in the clinical laboratory
The implementation of a robotic workstation in the clinical laboratory involves considerations and compromises common to any instrument design and development activity. The trade-off between speed and flexibility not only affects the way the instrument interacts with human operators and other devices (the 'real-world interface'), but also places limitations on the adaptation of chemistries to t...
متن کاملConnection Interface Designing for Grid and Mobile Devices
There area lot of mobile computer devices with a variety of applications and users Tend to use them more. Due to the limitations of mobile devices, running most of the procedures are impossible. To resolve this problem, mobile devices can be connected to the grid, to use the facilities of grid. On the other hand the communication mechanisms are different for each device and they cannot be c...
متن کاملConnection Interface Designing for Grid and Mobile Devices
There area lot of mobile computer devices with a variety of applications and users Tend to use them more. Due to the limitations of mobile devices, running most of the procedures are impossible. To resolve this problem, mobile devices can be connected to the grid, to use the facilities of grid. On the other hand the communication mechanisms are different for each device and they cannot be c...
متن کاملDesign and Implementation of the Robotic Platform
This paper describes the design and implementation of the Robotic Platform, an object-oriented development platform for robotic applications. The Robotic Platform includes servo control, trajectory generation, 3D simulation, a graphical user interface, and a math library. As opposed to distributed solutions, the Robotic Platform implements all these components on a single hardware platform (a s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 36 9 شماره
صفحات -
تاریخ انتشار 1990