Alkylpyrazines and other volatiles in cocoa liquors at pH 5 to 8, by Selected Ion Flow Tube-Mass Spectrometry (SIFT-MS).

نویسندگان

  • Yang Huang
  • Sheryl A Barringer
چکیده

UNLABELLED Cocoa beans were alkalized before or after roasting and made into cocoa liquor before analyzing by SIFT-MS. In both alkalized-before-roasting and alkalized-after-roasting samples, there were significantly higher concentrations of alkylpyrazines for the samples with pH above 7 than pH below 7. At pH 8, the concentrations of 2,3-, 2,5-, and 2,6-dimethylpyrazine (DMP), 2,3,5-trimethylpyrazine (TrMP), 2,3,5,6-tetramethylpyrazine (TMP), and 2,3-diethyl-5-methylpyrazine (EMP) in the samples alkalized-before-roasting were higher than those in the samples alkalized-after-roasting. Volatiles increased under conditions that promoted the Maillard reaction. The partition coefficient was not significantly affected by pH from 5.2 to 8. The ratios of TrMP/DMP and DMP/TMP increased while the ratio of TMP/TrMP decreased as the pH increased. The concentrations of Strecker aldehydes and other volatiles followed a similar pattern as that of the alkylpyrazines. High pH favors the production of alkylpyrazines and Strecker aldehydes. PRACTICAL APPLICATIONS Cocoa beans alkalized-before-roasting had higher levels of many important chocolate aroma volatiles than those alkalized-after-roasting. Thus, alkalizing before roasting should produce a stronger cocoa aroma. The higher the pH, the higher the concentrations of these important volatiles. There was little change in volatile concentration at acid pH. Above pH 7, volatile levels increased rapidly with increasing pH. To maintain the recommended ratio of tetramethylpyrazine to trimethylpyrazine, a longer roasting time or higher temperature is needed for cocoa liquor with a pH below 6.5, while a shorter roasting time or lower temperature is needed for cocoa liquor with a pH above 7.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Volatile generation in bell peppers during frozen storage and thawing using selected ion flow tube mass spectrometry (SIFT-MS).

UNLABELLED To determine volatile formation during storage and thawing, whole, pureed, blanched, and raw green and red bell peppers (Capsicum annuum) were frozen quickly or slowly then stored at -18 °C for up to 7 mo, with and without SnCl(2) addition during thawing. Headspace analysis was performed by a Selected Ion Flow Tube Mass Spectrometer (SIFT-MS). After blanching, (Z)-3-hexenal had a lar...

متن کامل

The Effect of pH and Temperature on Cabbage Volatiles During Storage.

During storage of shredded cabbage, characteristic sulfurous volatile compounds are formed affecting cabbage aroma both negatively and positively. Selected ion flow tube-mass spectrometry (SIFT-MS) was used to measure the concentration of cabbage volatiles during storage. The volatile levels of cabbage samples were measured at pH 3.3 to 7.4 at 4 °C for 14 d, and pH 3.3 at 25 °C for 5 d in order...

متن کامل

Selected ion flow-drift tube mass spectrometry, SIFDT-MS: quantification of volatile compounds in air and breath

A selected ion flow drift tube mass spectrometric analytical technique, SIFDT-MS, is described that extends the established selected ion flow tube mass spectrometry, SIFT-MS, by the inclusion of a static but variable E-field along the axis of the flow tube reactor in which the analytical ion-molecule chemistry occurs. The ion axial speed is increased in proportion to the reduced field strength ...

متن کامل

From molecules in space to molecules in breath.

The evolution of the selected ion flow tube, SIFT, used to study ion-molecule reactions of interstellar significance, to the selected ion flow tube mass spectrometry, SIFT-MS, analytical technique is described briefly. Focus is placed on the application of SIFT-MS to breath analysis and its potential for the detection of volatile biomarkers of disease including respiratory pathogens. Typical co...

متن کامل

Direct detection and quantification of malondialdehyde vapour in humid air using selected ion flow tube mass spectrometry supported by gas chromatography/mass spectrometry.

RATIONALE It has been proposed that malondialdehyde (MDA) reflects free oxygen-radical lipid peroxidation and can be useful as a biomarker to track this process. For the analysis of MDA molecules in humid air by selected ion flow tube mass spectrometry (SIFT-MS), the rate coefficients and the ion product distributions for the reactions of the SIFT-MS reagent ions with volatile MDA in the presen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of food science

دوره 75 1  شماره 

صفحات  -

تاریخ انتشار 2010