Fully refocused gradient recalled echo (FRGRE): factors affecting flow and motion sensitivity in cardiac MRI.

نویسندگان

  • Laurie B Hildebrand
  • Michael H Buonocore
چکیده

The Fully Refocused Gradient Recalled Echo (FRGRE) magnetic resonance pulse sequence, previously reported as True FISP, was implemented and reported on a GE Signa CV/i 1.5T scanner. The purpose of this research was to optimize the pulse sequence design and scanning parameters to improve image quality for cardiac applications. A 2-D, multi-slice, multi-phase, breathold, segmented k-space, prospectively gated FRGRE sequence was implemented with TE and TR values as short as 0.9 and 3.0 msec, respectively. Pulse sequence design changes were investigated theoretically in terms of moment calculations and by assessing the quality of long- and short-axis cardiac images. The most influential scanning parameter for the improvement of image quality was both a short TR and TE. Placement of the z gradient rephaser immediately before the slice select gradient reduced the accumulated moments and improved image quality. Increasing the slice thickness from 3 to 8-10 mm significantly reduced flow artifact. The number of views per segment was doubled, without decreasing image quality, cutting breathold time in half compared to cardiac scanning with conventional sequences with longer TRs. The optimal flip angle was approximately 60 degrees. The use of a full or fractional echo had no noticeable effect on image quality. Surprisingly, the addition of flow compensation pulses significantly decreased image quality. In summary, optimization of sequence design and scanning parameters significantly reduced flow artifacts seen in FRGRE images.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Refocused Turbo Spin Echo for Noncontrast MRA

Introduction There is increasing interest in non-contrast MRA methods because of the risk of NSF in patients with kidney disease [1]. RARE-type sequences are capable of generating contrast between blood and surrounding tissue based on T2 differences, but conventional RARE sequences have a non-zero first moment at the RF pulses and at odd echoes, and are therefore susceptible to flow-related art...

متن کامل

Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady state.

A novel, fully 3D, high-resolution T(1) and T(2) relaxation time mapping method is presented. The method is based on steady-state imaging with T(1) and T(2) information derived from either spoiling or fully refocusing the transverse magnetization following each excitation pulse. T(1) is extracted from a pair of spoiled gradient recalled echo (SPGR) images acquired at optimized flip angles. This...

متن کامل

A spin echo sequence with a single-sided bipolar diffusion gradient pulse to obtain snapshot diffusion weighted images in moving media.

In vivo MRI data can be corrupted by motion. Motion artifacts are particularly troublesome in Diffusion Weighted MRI (DWI), since the MR signal attenuation due to Brownian motion can be much less than the signal loss due to dephasing from other types of complex tissue motion, which can significantly degrade the estimation of self-diffusion coefficients, diffusion tensors, etc. This paper descri...

متن کامل

Quantification of thoracic aorta blood flow by magnetic resonance imaging during supine cycling exercise of increasing intensity

Background Cardiac magnetic resonance imaging (MRI) may be used for the diagnosis and follow-up of diseases affecting the thoracic aorta (TA). Typically, patients are imaged at rest. Quantifying TA blood flow distribution during activity may improve understanding of disease impact by assessing possible factors contributing to exercise intolerance. Blood flow quantification during exercise MRI, ...

متن کامل

اندازه گیری غیریکنواختی امواج رادیوئی در ام آر آی

Introduction: Non-uniformity is one of the most important parameters affecting MRI images which can lead to harmful effects in the diagnosis and analysis of qualitative and quantitative methods. The present study introduced a method for measuring RF non-homogeneity in MRI systems. Methods and Materials: To verify the uniformity of B0 and B1 fields, a cylindrical phantom with a diameter of 24 c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance

دوره 4 2  شماره 

صفحات  -

تاریخ انتشار 2002