A Comparative Study on the Influence of Probe Placement on Quality Assurance Measurements in B-mode Ultrasound by Means of Ultrasound Phantoms
نویسندگان
چکیده
To check or to prevent failures in ultrasound medical systems, some tests should be scheduled for both clinical suitability and technical functionality evaluation: among them, image quality assurance tests performed by technicians through ultrasound phantoms are widespread today and their results depend on issues related to scanner settings as well as phantom features and operator experience. In the present study variations on some features of the B-mode image were measured when the ultrasound probe is handled by the technician in a routine image quality test: ultrasound phantom images from two array transducers are processed to evaluate measurement dispersion in distance accuracy, high contrast spatial resolution and penetration depth when probe is handled by the operator. All measurements are done by means of an in-house image analysis software that minimizes errors due to operator's visual acuity and subjective judgment while influences of ultrasound transducer position on quality assurance test results are estimated as expanded uncertainties on parameters above (measurement reproducibility at 95 percent confidence level): depending on the probe model, they ranged from ±0.1 to ±1.9 mm in high contrast spatial resolution, from ±0.1 to ±5.5 percent in distance measurements error and from ±1 to ±10 mm in maximum depth of signal visualization. Although numerical results are limited to the two examined probes, they confirm some predictions based on general working principles of diagnostic ultrasound systems: (a) measurements strongly depend on settings as well on phantoms features, probes and parameters investigated; (b) relative uncertainty due to probe manipulation on spatial resolution can be very high, i.e. from 10 to more than 30 percent;
منابع مشابه
Temperature Mapping Using Ultrasound Digital Images
Introduction: The success of hyperthermia depends on the accuracy of the temperature monitoring in the tumor and the surrounding normal tissue. In this study, the temperature changes were determined by computing the speckle displacement in the ultrasound digital images. Speckle tracking algorithm was used to compute the displacement. Materials and Methods: The experiment was perf...
متن کاملComparative Studies on Ultrasound Pre-treated Peanut Husk Powder and Ultrasound Simultaneous Process on Heavy Metal Adsorption
The removal of copper (II) ion by using ultrasound pre-treatment to increase the pores structure and surface area on peanut husk powder via direct sonication (ultrasound probe) and indirect ultrasound (ultrasound bath) at powder level 3.5 W. In previous studies, researchers had applied ultrasound simultaneous with adsorption process. This method is not suitable to treat huge amount of heavy met...
متن کاملAutomatic measurement of instantaneous changes in the walls of carotid artery with sequential ultrasound images
Introduction: This study presents a computerized analyzing method for detection of instantaneous changes of far and near walls of the common carotid artery in sequential ultrasound images by applying the maximum gradient algorithm. Maximum gradient was modified and some characteristics were added from the dynamic programming algorithm for our applications. Methods: The algorithm was evaluat...
متن کاملFree hydroxyl radical dosimetry by using 1 MHz low level ultrasound waves
ABSTRACTBackground : In order to quantify effects of ultrasound irradiation parameters under therapeutic condition, especially sonodynamic therapy, it is initially necessary to evaluate inertial cavitation activity in vitro conditions therefore, in this study, the effect of 1 MHz low level ultrasound based on °OH radicals generated by acoustic inertial cavitation in aqueous solution was monit...
متن کاملDiagnostic Ultrasound Scanner Quality Assurance
Medical Physics at CancerCare Manitoba has developed its own ultrasound phantom. The following table is intended as a quick reference guide when performing the quality assurance measurements. Instructions Limits Record Items Required ultrasound contrast-detail phantom degassed water or coupling gel paper towels for clean up (optional) lab stand and clamp to hold probe Physical check: 1. probe s...
متن کامل