Background and purpose: To design a consistent set of criteria for acceptability of photon beam dose calculations of treatment planning systems. The set should be applicable in combination with a test package used for evaluation of a treatment planning system, such as the ones proposed by the AAPM Task Group 23 or by the Netherlands Commission on Radiation Dosimetry. Results: Tolerances have been de®ned for the accuracy with which a treatment planning system should be able to calculate the dose in different parts of a photon beam: the central beam axis and regions with large and small dose gradients. For increasing complexity of the geometry, wider tolerances are allowed, varying between 2 and 5%. For the evaluation of a large number of data points an additional quantity, the con®dence limit, has been introduced, which combines the in ̄uence of systematic and random deviations. The proposed tolerances have been compared with other recommendations for a number of clinically relevant examples, showing considerable differences, which are partly due to the way the complexity of the geometry is taken into account. Furthermore differences occur if criteria for acceptability of dose calculations are related either to the local dose value or to a normalized dose value. Conclusions: Although it is acknowledged that the general aim must be to have good agreement between dose calculation and the actual dose value, e.g. within 2% or 2 mm, current day algorithms and their implementation into commercial treatment planning systems result often in larger deviations. A high accuracy can at present only be achieved in relatively simple cases. The new set of tolerances and the quantity con®dence limit have proven to be useful tools for the acceptance of photon beam dose calculation algorithms of treatment planning systems. q 2001 Elsevier Science Ireland Ltd. All rights reserved.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pii: S0167-8140(01)00425-x

Background and purpose: Only limited data exist on the outcome of curative radiotherapy in patients who develop a second primary lung tumour after pneumonectomy. The treatment of eight such patients is described. Materials and methods: The case records of patients who underwent curative radiotherapy for stage I non-small cell lung cancer after a previous pneumonectomy were reviewed. Treatment w...

متن کامل

Pii: S0167-2231(01)00041-0

We construct a random matching model to study the effects of clearing arrangements for private money on the prices at which private monies trade, the volume of exchange, and welfare. In a model with full information, clearing arrangements eliminate discounts on private monies issued in other locations, the volume of exchange increases, and welfare increases. However, with private information ab...

متن کامل

Pii: S0167-8140(01)00430-3

Purpose: We report the results of hyperbaric oxygen therapy (HBO) used in the treatment of radiation cystitis and proctitis following irradiation of prostate cancer. Materials and methods: Between June 1995 and March 2000, 18 men (median age 71 years) with radiation proctitis (n 1⁄4 7), cystitis (n 1⁄4 8), and combined proctitis/cystitis (n 1⁄4 3) underwent HBO therapy in a multiplace chamber f...

متن کامل

Pii: S0167-8140(02)00078-6

Purpose: A systematic review was conducted to develop guidelines for radiotherapy in adult patients with newly diagnosed malignant glioma. Methods: MEDLINE, CANCERLIT, the Cochrane Library, and relevant conference proceedings were searched to identify randomized trials and meta-analyses. Results: Pooling of six randomized trials detected a significant survival benefit favouring post-operative r...

متن کامل

A real-time model of the cerebellar circuitry underlying classical conditioning: A combined simulation and robotics study

Although key components of the cerebellar circuitry relevant to classical conditioning have been identi"ed, the question how they act together is still unresolved. In this simulation study, we investigate a real-time model which captures basic anatomical and physiological properties of this system. We show that this model displays realistic learning performance over a range of inter-stimulus in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001