Fully integrated whole blood testing by real-time absorption measurement on a centrifugal platform.

نویسندگان

  • J Steigert
  • M Grumann
  • T Brenner
  • L Riegger
  • J Harter
  • R Zengerle
  • J Ducrée
چکیده

We present a novel microfluidic concept to enable a fast colorimetric alcohol assay from a single droplet of whole blood. The reduced turn-around time of 150 seconds is, on the one hand, achieved by a full process integration including metering, mixing with reagents, and sedimentation of cellular constituents. On the other hand, our novel total internal reflection (TIR) scheme allows to monitor the increase of the absorbance values in real-time. Thus, the saturation values can be predicted accurately based on an extrapolation of real-time measurements acquired during a 100 second initial period of rotation. Additionally, we present a metering structure to define nanolitre sample volumes at a coefficient of variation (CV) below 5%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sensitivity enhancement for colorimetric glucose assays on whole blood by on-chip beam-guidance.

In this paper, we present a novel concept for optical beam-guidance to significantly enhance the sensitivity of colorimetric assays by extending the optical path length through the detection cell which linearly impacts the resulting attenuation of a probe beam according to the law of Beer-Lambert. In our setup, the incident probe beam is deflected by 90( composite function) into the chip plane ...

متن کامل

Field Programmable Gate Array–based Implementation of an Improved Algorithm for Objects Distance Measurement (TECHNICAL NOTE)

In this work, the design of a low-cost, field programmable gate array (FPGA)-based digital hardware platform that implements image processing algorithms for real-time distance measurement is presented. Using embedded development kit (EDK) tools from Xilinx, the system is developed on a spartan3 / xc3s400, one of the common and low cost field programmable gate arrays from the Xilinx Spartan fami...

متن کامل

One-step White Blood Cell Separation from Whole Blood On a Centrifugal Microfluidic Device

In this work, we propose a fully automated WBCs isolation device from biological sample utilizing centrifugal microfluidics on a polymer based CD platform. Using the novel Laser Irradiated Ferrowax Microvalves (LIFM) and liquid density gradient medium on CD platform, the total process of a blood sample loading on the density gradient medium, fractionating to concentrate the WBC, decanting plasm...

متن کامل

Testing Measurement in Real -Time Reactive Systems

In the context of safety-critical systems, which are real-time reactive systems, testing process must be integrated with the software development process as a whole, not just with the end product. Consequently, measuring the efficiency of the testing process emerges as an important issue. To be accurate and meaningful, both the measurement and the components to be measured must be precisely des...

متن کامل

Fully integrated lab-on-a-disc for simultaneous analysis of biochemistry and immunoassay from whole blood.

We report a fully integrated device that can perform both multiple biochemical analysis and sandwich type immunoassay simultaneously on a disc. The whole blood is applied directly to the disposable "lab-on-a-disc" containing different kinds of freeze-dried reagents for the blood chemistry analysis as well as reagents required for the immunoassay. The concentrations of different kinds of analyte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Lab on a chip

دوره 6 8  شماره 

صفحات  -

تاریخ انتشار 2006