On the method of Hunt's parameter calibration.
نویسندگان
چکیده
This note comments on the observations of Bernier et al. (2016) regarding errors in Appendix A of Kim and Allen (2013). We acknowledge that the equations in the Appendix are in error, but wish to point out that these equations were not actually used for our analysis. We appreciate their effort in pointing out the errors, and offering corrected equations.
منابع مشابه
Calibration of Hardening Rules for Cyclic Plasticity
In the realm of multi-axial ratcheting, a step by step mathematical approach is developed for the parameter determination of decomposed kinematic hardening rules. For this purpose, key characteristics are mathematically derived for these hardening rules under multi-axial loading. These characteristics are then utilized to develop expressions which relate the loading history to the accumulated p...
متن کاملParameter Study of GTN Model in a SLM Manufactured Lattice Structure under Compression by Using FEM
This study investigates the effect of material parameters of the Gurson-Tvergaard-Needleman (GTN) model on the failure prediction of cellular structures. The effect of elastic modulus, calibration parameter of GTN model, isotropic hardening, fracture strain, and strut diameter on the load-displacement curve of a lattice structure fabricated by Selective Laser Melting (SLM) has been studied by u...
متن کاملReview and Comparison of In-field Calibration Methods of Accelerometer Based on Gravity Vector
Considering the wide applications of accelerometers to determine position and attitude and due to reducing of accuracy of this sensors because of some errors, this paper discusses the calibration of accelerometers. Also because the traditional calibration methods are very time consuming, costly and need precision laboratory equipment, in-field calibration methods are recommended which are simpl...
متن کاملLinking Item Parameters to a Base Scale
This paper compares three methods of item calibration—concurrent calibration, separate calibration with linking, and fixed item parameter calibration—that are frequently used for linking item parameters to a base scale. Concurrent and separate calibrations were implemented using BILOG-MG. The Stocking and Lord (1983) characteristic curve method of parameter linking was used in conjunction with ...
متن کاملSpectrophotometric Simultaneous Kinetic Determination of Iodide and Iodate Using Partial Least-Squares Calibration Method in a Single Kinetic Run
A rapid, sensitive and versatile kinetic method is presented for the simultaneous spectrophotometric determination of iodide and iodate by partial least-squares regression (PLS) using original and derivate data named as absorbance and rate data. The method is based on the catalytic effect of the cited anions on the reaction rate between Ce(IV) and As(III) in 2 mol l?1 sulfuric acid medium. The ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Hearing research
دوره 339 شماره
صفحات -
تاریخ انتشار 2016