Model-based quantitative laser Doppler flowmetry in skin.
نویسندگان
چکیده
Laser Doppler flowmetry (LDF) can be used for assessing the microcirculatory perfusion. However, conventional LDF (cLDF) gives only a relative perfusion estimate for an unknown measurement volume, with no information about the blood flow speed distribution. To overcome these limitations, a model-based analysis method for quantitative LDF (qLDF) is proposed. The method uses inverse Monte Carlo technique with an adaptive three-layer skin model. By analyzing the optimal model where measured and simulated LDF spectra detected at two different source-detector separations match, the absolute microcirculatory perfusion for a specified speed region in a predefined volume is determined. qLDF displayed errors<12% when evaluated using simulations of physiologically relevant variations in the layer structure, in the optical properties of static tissue, and in blood absorption. Inhomogeneous models containing small blood vessels, hair, and sweat glands displayed errors<5%. Evaluation models containing single larger blood vessels displayed significant errors but could be dismissed by residual analysis. In vivo measurements using local heat provocation displayed a higher perfusion increase with qLDF than cLDF, due to nonlinear effects in the latter. The qLDF showed that the perfusion increase occurred due to an increased amount of red blood cells with a speed>1 mm∕s.
منابع مشابه
Evaluation of Carpal Tunnel Syndrome by Laser Doppler Flowmetry
Background:Autonomic disturbance can leads to blood flow changes that can be studied by various methods. Objective: To assess the blood flow changes in patients with severe carpal tunnel syndrome by laser Doppler flowmetry Methods:Ten patients with severe unilateral carpal tunnel syndrome confirmed by electrodiagnostic examination enrolled in this study. Patients comprised one man and nine wom...
متن کاملCombined use of laser Doppler flowmetry and skin thermometry for functional diagnostics of intradermal finger vessels.
We introduce a noninvasive diagnostic approach for functional monitoring of blood microflows in capillaries and thermoregulatory vessels within the skin. The measuring system is based on the combined use of laser Doppler flowmetry and skin contact thermometry. The obtained results suggest that monitoring of blood microcirculation during the occlusion, performed in conjunction with the skin temp...
متن کاملConcurrent Reflectance Confocal Microscopy and Laser Doppler Flowmetry to Improve Skin Cancer Imaging: A Monte Carlo Model and Experimental Validation
Optical interrogation of suspicious skin lesions is standard care in the management of skin cancer worldwide. Morphological and functional markers of malignancy are often combined to improve expert human diagnostic power. We propose the evaluation of the combination of two independent optical biomarkers of skin tumours concurrently. The morphological modality of reflectance confocal microscopy ...
متن کاملMeasurement depth and volume in laser Doppler flowmetry.
A new method for estimating the measurement depth and volume in laser Doppler flowmetry (LDF) is presented. The method is based on Monte Carlo simulations of light propagation in tissue. The contribution from each individual Doppler shift is calculated and thereby multiple Doppler shifts are handled correctly. Different LDF setups for both probe based (0.0, 0.25, 0.5, and 1.2 mm source-detector...
متن کاملQuantitative Laser Doppler Flowmetry
vii-Abstract Laser Doppler flowmetry (LDF) is virtually the only non-invasive technique, except for other laser speckle based techniques, that enables estimation of the microcirculatory blood flow. The technique was introduced into the field of biomedical engineering in the 1970s, and a rapid evolvement followed during the 1980s with fiber based systems and improved signal analysis. The first i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of biomedical optics
دوره 15 5 شماره
صفحات -
تاریخ انتشار 2010