Stress Analysis of a Total Hip Replacement Subjected to Realistic Loading Conditions

نویسنده

  • Mohammad Rabbani
چکیده

In this paper the stress distribution of a complete assembly of femur and hip prosthesis is investigated with realistic boundary conditions under nine routine activities using finite element analysis. In each activity, different forces of varying magnitude and orientation were applied on the prosthesis during a period of time to examine the critical points developed in the entire 3D model. This includes a full description of the geometry, material properties and the boundary conditions. The activities considered comprise slow walking, normal walking, fast walking, upstairs, down stairs, standing up, sitting down, and standing on 2-1-2 legs and knee bending. The findings of this study can be used to develop more optimized hip joint prosthesis by altering the prosthesis geometry to achieve a more balanced stress distribution.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Finite Element Analysis of Different Hip Implant Designs along with Femur under Static Loading Conditions

Background: The hip joint is the largest joint after the knee, which gives stability to the whole human structure. The hip joint consists of a femoral head which articulates with the acetabulum. Due to age and wear between the joints, these joints need to be replaced with implants which can function just as a natural joint. Since the early 19th century, the hip joint arthroplasty has evolved, a...

متن کامل

Contact mechanics of modular metal-on-polyethylene total hip replacement under adverse edge loading conditions

Edge loading can negatively impact the biomechanics and long-term performance of hip replacements. Although edge loading has been widely investigated for hard-on-hard articulations, limited work has been conducted for hard-on-soft combinations. The aim of the present study was to investigate edge loading and its effect on the contact mechanics of a modular metal-on-polyethylene (MoP) total hip ...

متن کامل

Analysis of stress distribution around total hip stems custom-designed for the standardized Asian femur configuration

In total hip replacement (THR), bone resorption related to the foreign body reaction around the implant causes bonding failure at the bone-prosthesis interface and adversely affects the function and longevity of femoral implants. Stress shielding is thought to be one of the possible biomechanical factors that causes bone resorption, and is related to prosthesis design. We therefore investigated...

متن کامل

Determination of Residual Stress for Single and Double Autofrettage of Thick-walled FG Cylinders Subjected to Dynamic Loading

In the present article a numerical procedure is developed for dynamic analysis of single and double autofrettage of thick–walled FG cylinders under transient loading. The governing differential equations are discretized and presented in explicit Lagrangian formalism. The explicit transient solution of discrete equations are obtained on the meshed region and results for stress and strain distrib...

متن کامل

Hot Spot Stress Determination for a Tubular T-Joint under Combined Axial and Bending Loading

Finite element analysis of a tubular T-joint subjected to various loading conditions including pure axial loading, pure in-plane bending (IPB) and different ratios of axial loading to in-plane bending loading has been carried out. This effort has been established to estimate magnitudes of the peak hot spot stresses (HSS) at the brace/chord intersection and to find the corresponding locations as...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015