Endotracheal intubation attempts during neonatal resuscitation: success rates, duration, and adverse effects.

نویسندگان

  • Colm P F O'Donnell
  • C Omar F Kamlin
  • Peter G Davis
  • Colin J Morley
چکیده

OBJECTIVE Endotracheal intubation of newborn infants is a mandatory competence for many pediatric trainees. The Neonatal Resuscitation Program recommends a 20-second limit for intubation attempts. Intubation attempts by junior doctors are frequently unsuccessful, and many infants are intubated between 20 and 30 seconds without apparent adverse effect. Little is known about the proficiency of more senior medical staff, the time taken to determine endotracheal tube (ETT) position, or the effects of attempted intubation on infants' heart rate (HR) and oxygen saturation (Spo2) in the delivery room (DR). The objectives of this study were to determine (1) the success rates and duration of intubation attempts during DR resuscitation, (2) whether experience is associated with greater success rates and shorter time taken to intubate, (3) the time taken to identify ETT position after intubation, and (4) the frequency with which infants deteriorated during intubation attempts and the time at which this occurred. METHODS We reviewed videos of DR resuscitations; identified whether intubation was attempted; and, when attempted, whether intubation was attempted by a resident, a fellow, or a consultant. We defined the duration of an intubation attempt as the time from the introduction of the laryngoscope blade to the mouth to its removal, regardless of whether an ETT was introduced. We determined the time from removal of the laryngoscope to the clinicians' decision as to whether the intubation was successful and noted the basis on which this decision was made (clinical assessment, flow signals, or exhaled carbon dioxide [ETCO2] detection). We determined success according to clinical signs in all cases and used flow signals that were obtained during ventilation via the ETT or ETCO2 when available. When neither was available, the chest radiograph on admission to the NICU was reviewed. For infants who were monitored with pulse oximetry, we determined their HR and Spo2 before the intubation attempt. We then determined whether either or both fell by > or =10% during the attempt and, if so, at what time it occurred. RESULTS We reviewed 122 video recordings in which orotracheal intubation was attempted 60 times in 31 infants. We secondarily verified ETT position using flow signals, ETCO2, or chest radiographs after 94% of attempts in which an ETT was introduced. Thirty-seven (62%) attempts were successful. Success rates and mean (SD) time to intubate successfully by group were as follows: residents: 24%, 49 seconds (13 seconds); fellows: 78%, 32 seconds (13 seconds); and consultants: 86%, 25 seconds (17 seconds). Of the 23 unsuccessful attempts, 13 were abandoned without an attempt to pass an ETT and 10 were placed incorrectly. The time to determine ETT position in the DR was longer when clinical assessment alone was used. Infants who were monitored with oximetry deteriorated during nearly half of the intubation attempts. Deterioration seemed more likely when HR and Spo2 were low before the attempt. CONCLUSIONS Intubation attempts often are unsuccessful, and successful attempts frequently take >30 seconds. Greater experience is associated with greater success rates and shorter duration of successful attempts. Flow signals and ETCO2 may be useful in determining ETT position more quickly than clinical assessment alone. Infants frequently deteriorate during intubation attempts. Improved monitoring of infants who are resuscitated in the DR is desirable.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Recent advances in genetics in relation to pediatrics.

Corp; 2004. 15. Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;8476:307-10. 16. Bland JM, Altman DG. Measuring agreement in method comparison studies. Stat Methods Med Res 1999;8:135-60. 17. Finer NN, Carlo WA, Duara S, Fanaroff AA, Donovan EF, Wright LL, et al. Delivery room continuous positive airway pressure/positive ...

متن کامل

Randomized, controlled trial comparing laryngeal mask versus endotracheal intubation during neonatal resuscitation---a secondary publication

BACKGROUND This study aimed to study the feasibility, efficacy and safety of using laryngeal mask (LM) ventilation compared with endotracheal intubation (ETI) during neonatal resuscitation. METHODS Neonates with a heart rate below 60 beats per minute despite 30 s of face mask ventilation were assigned quasi-randomly (odd/even birth date) to LM (n = 36) or ETI (n = 32) ventilation. Differences...

متن کامل

Improving neonatal intubation safety: A journey of a thousand miles.

Neonatal intubation is one of the most common procedures performed by neonatologists, however, the procedure is difficult and high risk. Neonates who endure the procedure often experience adverse events, including bradycardia and severe oxygen desaturations. Because of low first attempt success rates, neonates are often subjected to multiple intubation attempts before the endotracheal tube is s...

متن کامل

Comparison between Glidescope and Lightwand for tracheal intubation in patients with a simulated difficult airway

BACKGROUND Although Lightwand and Glidescope have both shown high success rates for intubation, there has been no confirmation as to which device is most effective for difficult endotracheal intubation. We compared the Glidescope and Lightwand devices in terms of duration of intubation and success rate at the first attempt in a simulated difficult airway situation. METHODS Fifty-eight patient...

متن کامل

Morphine for elective endotracheal intubation in neonates: a randomized trial [ISRCTN43546373]

BACKGROUND Elective endotracheal intubations are still commonly performed without premedication in many institutions. The hypothesis tested in this study was that morphine given prior to elective intubations in neonates would decrease fluctuations in vital signs, shorten the duration of intubation and reduce the number of attempts. METHODS From December 1999 to September 2000, infants of all ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Pediatrics

دوره 117 1  شماره 

صفحات  -

تاریخ انتشار 2006