Changes in Center of Rotation and Load Sharing Characteristics Following Posterior Dynamic Stabilization in the Lumbar Spine
نویسندگان
چکیده
Changes in Center of Rotation and Load Sharing Characteristics Following Posterior Dynamic Stabilization in the Lumbar Spine Yoon-Ho Ahn1, Kyung-Woo Park2, Wen-Ming Chen3, Jae-Won Lee1, Duk-Young Jung4, Sung-Jae Lee1 1Department of Biomedical Engineering, Inje University, Gimhae, South Korea; 2Department of Neurosurgery, Kwang-Hye Spine Hospital, Seoul, South Korea; 3Division of Bioengineering, National University of Singapore, Singapore, Singapore; 4Division of Medical Devices, National Institute of Health Sciences, Tokyo, Japan [email protected]
منابع مشابه
Biomechanical Evaluation of Pedicle Screw-Based Dynamic Stabilization Devices for the Lumbar Spine: A Systematic Review
STUDY DESIGN This study is a systematic review of published biomechanical studies involving pedicle screw-based posterior dynamic stabilization devices (PDS) with a special focus on kinematics and load transmission through the functional spine unit (FSU). METHODS A literature search was performed via the PubMed online database from 1990 to 2008 using the following key words: "biomechanics," "...
متن کاملبررسی تغییرات الگوی کنترل حرکت ستون فقرات کمری بهدنبال افزایش مقاومت: مطالعه کلینیکی
Background: Joint trauma and injury are the most common causes of dynamic instability. Dynamic instability has a great effect on the lumbar spine, due to its three-dimensional motions. The greatest amounts of compression and shearing force are imposed at the points of maximum torque and velocity. The changes in these phase angles upon bearing various loads can cause some pathologic conditions. ...
متن کاملComparison of the load-sharing characteristics
Recently, numerous types of posterior dynamic stabilization (PDS) devices have been introduced as an alternative to the fusion devices for the surgical treatment of degenerative lumbar spine. It is hypothesized that the use of ‘compliant’ materials such as Nitinol (Ni–Ti alloy, elastic modulus = 75 GPa) or polyether-etherketone (PEEK, elastic modulus = 3.2 GPa) in PDS can restore stability of t...
متن کاملStability and Load Sharing Characteristics of a Posterior Dynamic Stabilization Device
BACKGROUND Lumbar interbody fusion is a common treatment for a variety of spinal pathologies. It has been hypothesized that insufficient mechanical loading of the interbody graft can prevent proper fusion of the joint. The purpose of this study was to evaluate the mechanical stability and anterior column loading sharing characteristics of a posterior dynamic system compared to titanium rods in ...
متن کاملEffect of Device Rigidity and Physiological Loading on Spinal Kinematics after Dynamic Stabilization : An In-Vitro Biomechanical Study.
OBJECTIVE To investigate the effects of posterior implant rigidity on spinal kinematics at adjacent levels by utilizing a cadaveric spine model with simulated physiological loading. METHODS Five human lumbar spinal specimens (L3 to S1) were obtained and checked for abnormalities. The fresh specimens were stripped of muscle tissue, with care taken to preserve the spinal ligaments and facet joi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2002