Phase-sensitive sodium B1 mapping.
نویسندگان
چکیده
Quantitative sodium MRI requires accurate knowledge of factors affecting the sodium signal. One important determinant of sodium signal level is the transmit B(1) field strength. However, the low signal-to-noise ratio typical of sodium MRI makes accurate B(1) mapping in reasonable scan times challenging. A new phase-sensitive B(1) mapping technique has recently been shown to work better than the widely used dual-angle method in low-signal-to-noise ratio situations and over a broader range of flip angles. In this work, the phase-sensitive B(1) mapping technique is applied to sodium, and its performance compared to the dual-angle method through both simulation and phantom studies. The phase-sensitive method is shown to yield higher quality B(1) maps at low signal-to-noise ratio and greater consistency of measurement than the dual-angle method. An in vivo sodium B(1) map of the human breast is also shown, demonstrating the phase-sensitive method's feasibility for human studies.
منابع مشابه
3D Phase Sensitive B1 Mapping
INTRODUCTION: Sodium MRI shows promise in assessing cartilage health [1], characterizing tumors [2], detecting abnormal sodium levels in the kidneys [3], and assessing tissue damage following stroke [4]. However, relatively low Na concentrations in biological tissues, a rapid biexponential signal decay, and a low gyromagnetic ratio make sodium MRI challenging. Recent improvements in MRI hardwar...
متن کاملSA2RAGE: a new sequence for fast B1+ -mapping.
At high magnetic field strengths (≥ 3T), the radiofrequency wavelength used in MRI is of the same order of magnitude of (or smaller than) the typical sample size, making transmit magnetic field (B1+) inhomogeneities more prominent. Methods such as radiofrequency-shimming and transmit SENSE have been proposed to mitigate these undesirable effects. A prerequisite for such approaches is an accurat...
متن کاملPHASE - SENSITIVE AND DUAL - ANGLE RADIOFREQUENCY MAPPING IN 23 NA MAGNETIC RESONANCE IMAGING by Steven
PHASE-SENSITIVE AND DUAL-ANGLE RADIOFREQUENCY MAPPING IN NA MAGNETIC RESONANCE IMAGING Steven P. Allen Department of Physics and Astronomy Bachelor of Science Many diagnostic applications in sodium magnetic resonance imaging (MRI) require accurate flip angle mapping. In search for a mapping technique that performs well in sodium MRI, we evaluated the low signal-to-noise ratio performance of the...
متن کاملRegularized Estimation of Magnitude and Phase of Multi-Coil $B_1$ Field Via Bloch-Siegert $B_1$ Mapping and Coil Combination Optimizations
Parallel excitation requires fast and accurate B1 map estimation. Bloch-Siegert (BS) B1 mapping is very fast and accurate over a large dynamic range. When applied to multi-coil systems, however, this phase-based method may produce low signal-to-noise ratio estimates in low magnitude regions due to localized excitation patterns of parallel excitation systems. Also, the imaging time increases wit...
متن کاملTurbo Spin Echo Bloch Siegert Shift B1 Mapping
An interesting method for B1 mapping based on the Bloch-Siegert (BLS) shift was recently presented (1,2) for gradient echo (FLASH) and Spin Echo (SE) sequences. This method uses off-resonant pulses before signal acquisition to encode the B1 information into the signal phase. Fast B1 mapping is possible since the repetition time has only minor influence on the quality of the phase information. I...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Magnetic resonance in medicine
دوره 65 4 شماره
صفحات -
تاریخ انتشار 2011