Clinical application of the flow-volume loop.
نویسندگان
چکیده
A convenient method for recording pulmonary function which allows for rapid graphic bedside analysis was presented. The method involves recording flow-volume (‘V-V) loop, in correct alignment to a previously determined FRC. FRC was measured by a rapid nitrogen dilution method. This method of recording pulmonary function affords a composite of TLC and all subdivisions with corresponding flow which can be recorded in a patient’s chart similar to ECGs. Normal and pathologic loop patterns are illustrated. A high statistical correlation of volumes and flows by the method was found when compared to conventional spirograms in 90 patients.
منابع مشابه
بررسی شکل منحنی جریان و حجم در ضایعات انسدادی کارینا و برونش
Spirometry and flow - volume loop show the abnormal pattern of pulmonary dysfunction and the site of the obstruction of upper and peripheral airways. For determinig the shape of flow - volume loop in obstruction of carina and bronchus we examined 19 patients with large airway obstruction documented with fiberoptic bronchoscopy via pulmonary function testing and flow volume loop performing. Two...
متن کاملبررسی زاویه بتا در منحنی جریان - حجم در بیماران مبتلا به انسداد راههای هوائی
It is known that spiromentry is the most conventional method to determine pulmonary function. In spirometry, the shape of flow-volume loop is the most helpful finding to evaluate pulmonary dysfunction. Obstruction is best demonstrated by the slope of the descending portln of the exhalation curve. Measurement of fJ-angle is helpful for determination of this slope. fJ-angle is defined by 3 points...
متن کاملPressure-Velocity Coupled Finite Volume Solution of Steady Incompressible Invscid Flow Using Artificial Compressibility Technique
Application of the computer simulation for solving the incompressible flow problems motivates developing efficient and accurate numerical models. The set of Inviscid Incompressible Euler equations can be applied for wide range of engineering applications. For the steady state problems, the equation of continuity can be simultaneously solved with the equations of motion in a coupled manner using...
متن کاملBlood Flow Simulation in an Aorta with a mild coarctation Using Magnetic Resonance Angiography and Finite Volume Method
Coarctation of the aorta is one of the five main congenital cardiovascular failures, accounting for 6–8 percent of these failures. This research aimed to simulate the blood flow of a seventeen-year-old male teen with a mild coarctation at one-third of his aorta's descending branch. The simulation was performed by extracting the domain and the input pulsatile velocity signal as the boundary cond...
متن کاملShort Term Clinical Outcomes of Hook Plate Compared to Continuous Loop Double Endobutton Fixations in Acute Acromioclavicular Joint Dislocation
Background: This study was conducted to evaluate the clinical outcomes of acromioclavicular joint (ACJ) fixation with hook plate (HP) and continuous loop double endobutton fixation (CLDE) in treatment of the acute acromioclavicular joint (ACJ) dislocation. Methods: In this retrospective study, 8 patients with HP and 9 patients with CLDE fixations were compared for acute ACJ dislocations. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Diseases of the chest
دوره 55 2 شماره
صفحات -
تاریخ انتشار 1969