An intracranial pressure-derived index monitored simultaneously from two separate sensors in patients with cerebral bleeds: comparison of findings

نویسندگان

  • Per Kristian Eide
  • Wilhelm Sorteberg
چکیده

BACKGROUND In an attempt to characterize the intracranial pressure-volume compensatory reserve capacity, the correlation coefficient (R) between the ICP wave amplitude (A) and the ICP (P) level (RAP) has been applied in the surveillance of neurosurgical patients. However, as the ICP level may become altered by electrostatic discharges, human factors, technical factors and technology issues related to the ICP sensors, erroneous ICP scores may become revealed to the physician, and also become incorporated into the calculated RAP index. To evaluate the problem with regard to the RAP, we compared simultaneous RAP values from two separate ICP signals in the same patient. MATERIALS AND METHODS We retrieved our recordings in 20 patients with cerebral bleeds wherein the ICP had been recorded simultaneously from two different sensors. Sensor 1 was always a solid sensor while sensor 2 was a solid sensor (Category A), a fluid sensor (Category B), an air-pouch sensor (Category C), or a fibre-optic sensor (Category D). The simultaneous signals were analyzed with automatic identification of the cardiac induced ICP waves, with subsequent determination and comparison of the Pearson correlation coefficient between mean wave amplitude (MWA) and mean ICP (RAP) for 40 6-s time windows every 4-min period. RESULTS A total of 23,056 4-min RAP observations were compared. A difference in RAP≥0.4 between the two signals was seen in 4% of the observations in Category A-, in 44% of observations in Category B-, in 20% of observations in Category C-, and in 28% of observations in Category D patients, respectively. Moreover, the combination of a RAP of <0.6 in one signal and ≥0.6 in the other was seen in >20% of scores in 3/5 Category A-, in 3/5 Category B-, in 5/7 Category C- and 1/3 Category D patients. CONCLUSIONS Simultaneous monitoring of the ICP-derived index RAP from two separate ICP sensors reveals marked differences in the index values. These differences in RAP may be explained by erroneous scoring of the ICP level. This will hamper the usefulness of RAP as a guide in the management of neurosurgical patients.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous monitoring of static and dynamic intracranial pressure parameters from two separate sensors in patients with cerebral bleeds: comparison of findings

BACKGROUND We recently reported that in an experimental setting the zero pressure level of solid intracranial pressure (ICP) sensors can be altered by electrostatics discharges. Changes in the zero pressure level would alter the ICP level (mean ICP); whether spontaneous changes in mean ICP happen in clinical settings is not known. This can be addressed by comparing the ICP parameters level and ...

متن کامل

Cerebral Angiographic Findings in Non-Traumatic Intracranial Hemorrhage: A Single Center Experience in the West of Iran

Background and Aim: This study aimed at analyzing the demographic characteristics of the patients with non-traumatic intracranial hemorrhage, their angiographic results and the correlation between computed tomography (CT) scan and angiography findings. Methods and Materials/Patients: In a descriptive study, we retrospectively reviewed the records of the patients with non-traumatic intracranial...

متن کامل

Noninvasive evaluation of dynamic cerebrovascular autoregulation using Finapres plethysmograph and transcranial Doppler.

BACKGROUND AND PURPOSE Mx is an index of cerebrovascular autoregulation. It is calculated as the correlation coefficient between slow spontaneous fluctuations of cerebral perfusion pressure (cerebral perfusion pressure=arterial blood pressure-intracranial pressure) and cerebral blood flow velocity. Mx can be estimated noninvasively (nMxa) with the use of a finger plethysmograph arterial blood p...

متن کامل

The Experimental Study of Increased ICP on Cerebral Hemorrhage Rabbits with Magnetic Induction Phase Shift Method

Introduction Measuring magnetic induction phase shift (MIPS) changes as a function of cerebral hemorrhage volume has the potential for being a simple method for primary and non-contact detection of the occurrence and progress of cerebral hemorrhage. Our previous MIPS study showed that the intracranial pressure (ICP) was used as a contrast index and found the primary correlation between MIPS and...

متن کامل

The effect of baseline pressure errors on an intracranial pressure-derived index: results of a prospective observational study

BACKGROUND In order to characterize the intracranial pressure-volume reserve capacity, the correlation coefficient (R) between the ICP wave amplitude (A) and the mean ICP level (P), the RAP index, has been used to improve the diagnostic value of ICP monitoring. Baseline pressure errors (BPEs), caused by spontaneous shifts or drifts in baseline pressure, cause erroneous readings of mean ICP. Con...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2013