How to measure intraocular pressure: Schiötz tonometry

نویسنده

  • Sue Stevens
چکیده

If glaucoma is diagnosed early, treatment can then be given that may preserve vision. Although raised intraocular pressure (IOP) is not the only sign of glaucoma, the IOP should be checked routinely on all adults attending eye care facilities. Applanation tonometry (as described in Issue 64, December 2007) is the most accurate method to measure IOP, but Schiötz tonometry is also a useful screening test. If Schiötz tonometry reveals a high IOP, this result should be checked and confirmed by applanation tonometry and the patient referred to the senior clinician at the eye clinic.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

How to measure intraocular pressure: applanation tonometry

Unless there is a contraindication (e.g. trauma or corneal ulcer), all adults attending an eye unit should have their intraocular pressure (IOP) measured. Many people with glaucoma have no symptoms and do not know they have the condition. All children who have had cataract surgery should also have their IOP measured at every follow-up visit, if possible. Finding glaucoma early allows treatment ...

متن کامل

Comparison of intraocular pressure measurement between rebound, non-contact and Goldmann applanation tonometry in treated glaucoma patients.

BACKGROUND To compare the intraocular pressure readings obtained with the iCare rebound tonometer and the 7CR non-contact tonometer with those measured by Goldmann applanation tonometry in treated glaucoma patients. DESIGN A prospective, cross-sectional study was conducted in a private tertiary glaucoma clinic. PARTICIPANTS OR SAMPLES One hundred nine (54 males : 55 females) patients includ...

متن کامل

Dynamic contour tonometry and goldman applanation tonometry in eyes with keratoconus.

PURPOSE The dynamic contour tonometer is a nonapplanation contact tonometer designed to be largely independent of the structural properties of the cornea. Theoretically, it may measure intraocular pressure most accurately in abnormally thinner corneas. This study compares intraocular pressure measurements by dynamic contour tonometry with Goldman applanation tonometry in eyes with normal cornea...

متن کامل

Correlation between diurnal variation of intraocular pressure, ocular pulse amplitude and corneal structural properties.

PURPOSE The purpose of this study was to evaluate the fluctuation of intraocular pressure measurements obtained by Goldmann applanation tonometry, dynamic contour tonometry, and corneal compensated non-contact tonometry during office hours in glaucoma and healthy participants. This study also aims at correlating the intraocular pressure fluctuations with fluctuations of corneal hysteresis, cent...

متن کامل

CLINICAL SCIENCE Can We Measure Corneal Biomechanical Changes After Collagen Cross-Linking in Eyes With Keratoconus?—A Pilot Study

Methods: Ten eyes of 10 patients aged 26.5 6 5.7 (mean 6 SD) years with progressive keratoconus were treated with UV-A– riboflavin CXL and assessed with the Ocular Response Analyzer (ORA) that measured corneal hysteresis (CH), corneal resistance factor (CRF), Goldmann-correlated intraocular pressure (IOPg), and corneal compensated intraocular pressure (IOPcc). Intraocular pressure was also meas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Community Eye Health

دوره 21  شماره 

صفحات  -

تاریخ انتشار 2008