SVD-Based Evaluation of Multiplexing in Multipinhole SPECT Systems

نویسندگان

  • Aaron Kerry Jorgensen
  • Gengsheng Lawrence Zeng
چکیده

Multipinhole SPECT system design is largely a trial-and-error process. General principles can give system designers a general idea of how a system with certain characteristics will perform. However, the specific performance of any particular system is unknown before the system is tested. The development of an objective evaluation method that is not based on experimentation would facilitate the optimization of multipinhole systems. We derive a figure of merit for prediction of SPECT system performance based on the entire singular value spectrum of the system. This figure of merit contains significantly more information than the condition number of the system, and is therefore more revealing of system performance. This figure is then compared with simulated results of several SPECT systems and is shown to correlate well to the results of the simulations. The proposed figure of merit is useful for predicting system performance, but additional steps could be taken to improve its accuracy and applicability. The limits of the proposed method are discussed, and possible improvements to it are proposed.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of simultaneous dual-isotope multipinhole SPECT with rotational SPECT in a group of patients with coronary artery disease.

UNLABELLED A triple-detector, multipinhole SPECT system was optimally configured to perform simultaneous (201)Tl (stress)/(99m)Tc (rest) myocardial perfusion imaging (MPI) using a protocol that permitted direct diagnostic comparison of this multipinhole SPECT system with conventional rotational SPECT. METHODS Both the rotational and the multipinhole SPECT systems used the same model gamma-det...

متن کامل

Collimator design for a multipinhole brain SPECT insert for MRI.

PURPOSE Brain single photon emission computed tomography (SPECT) imaging is an important clinical tool, with unique tracers for studying neurological diseases. Nowadays, most commercial SPECT systems are combined with x-ray computed tomography (CT) in so-called SPECT/CT systems to obtain an anatomical background for the functional information. However, while CT images have a high spatial resolu...

متن کامل

Optimal SVD-based Precoding for Secret Key Extraction from Correlated OFDM Sub-Channels

Secret key extraction is a crucial issue in physical layer security and a less complex and, at the same time, a more robust scheme for the next generation of 5G and beyond. Unlike previous works on this topic, in which Orthogonal Frequency Division Multiplexing (OFDM) sub-channels were considered to be independent, the effect of correlation between sub-channels on the secret key rate is address...

متن کامل

A skew-slit collimator for small-animal SPECT.

UNLABELLED The main objective of this work was the development of a skew-slit collimator for small-animal SPECT to replace the state-of-the-art multipinhole collimator. METHODS A pinhole forms a cone-beam imaging geometry. If the collimator rotates around the object in a circular orbit, the projection measurements acquired by the cone-beam imaging geometry are incomplete and not enough for ar...

متن کامل

Reproducibility of serial left ventricle perfusion, volume, and ejection fraction measurements using multiplexed multipinhole SPECT in healthy rats and rats after myocardial infarction.

UNLABELLED Assessment of small-animal cardiac data acquired using SPECT requires an accurate understanding of the reproducibility and the uncertainties associated with the technique. Furthermore, it is also useful to have a baseline of reference data against which to compare the outcome of a particular study. METHODS We scanned both healthy and post-myocardial infarction rats injected with (9...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • International Journal of Biomedical Imaging

دوره 2008  شماره 

صفحات  -

تاریخ انتشار 2008