Total thyroidectomy for non-toxic multinodular goiter with versus without the use of harmonic FOCUS dissecting shears – a prospective randomized study

نویسندگان

  • Aleksander Konturek
  • Marcin Barczyński
  • Małgorzata Stopa
  • Wojciech Nowak
چکیده

INTRODUCTION Thyroidectomy is among the most commonly performed procedures involving the endocrine glands and the development of advanced surgical methods combined with a strife for performing the operation in a manner that is minimally invasive for the patient has considerably increased the need for instruments that would limit surgical trauma. AIM To compare of the outcomes of total thyroidectomy operations with and without the use of ultrasonic harmonic FOCUS dissecting shears. MATERIAL AND METHODS Eighty-two patients with a bilateral, non-toxic multinodular goiter were randomized to two groups of 41 patients each. Total thyroidectomy was performed in each patient. In the clip-ligation group (CL-G), during thyroidectomy, the superior thyroid vessels were clipped and bipolar coagulation was used to secure smaller vessels, whereas in the harmonic FOCUS group (HF-G), a harmonic device was used to dissect and divide all the thyroid vessels. The statistical analysis included the mean operative time, blood loss, postoperative morbidity and cost-effectiveness. RESULTS HF-G vs. CL-G operations were shorter (45.4 ±8.7 min vs. 64.5 ±14.2 min; p < 0.001), characterized by a lower mean blood loss (29.9 ±9.8 ml vs. 56.8 ±11.0 ml; p < 0.001) and appeared to be more cost-effective (666.2 ±37.5 EUR vs. 718.0 ±69.2 EUR; p < 0.01). No major complications were observed in both groups. CONCLUSIONS In total thyroidectomy operations, the harmonic FOCUS is safe and facilitates dissection, allowing for a significant decrease in operative time. Other benefits include lower blood loss and a slightly decreased cost of the procedure.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Total Thyroidectomy versus Bilateral Subtotal Thyroidectomy for Bilateral Multinodular Nontoxic Goiter: A Meta-Analysis.

AIM The aim of this meta-analysis is to assess and validate the feasibility and safety of total thyroidectomy (TT) when compared to bilateral subtotal thyroidectomy (BST) for bilateral multinodular nontoxic goiter (BMNG). MATERIALS AND METHODS PubMed, Web of Knowledge, and Ovid's database were searched for studies published in English language between January 1990 and December 2014. A meta-an...

متن کامل

Incidence of malignancy in non toxic multi-nodular goiter an institutional experience

The objective of the study is to determine the incidence of malignancy in non toxic multinodular goiter patients who underwent thyroid surgery in our institution. This is a prospective study carried out in the Department of general surgery, Liaquat University of Medical & Health Sciences Hospital Jamshoro, from January 2011 to December 2011. A total no. of 95 cases with clinical diagnosis as no...

متن کامل

The advantage of total thyroidectomy to avoid reoperation for incidental thyroid cancer in multinodular goiter.

HYPOTHESIS To investigate the impact of total thyroidectomy on the rate of completion thyroidectomy for incidentally found thyroid cancer in euthyroid multinodular goiter. DESIGN A randomized, prospective clinical trial. SETTING A tertiary referral center. PATIENTS Patients with euthyroid multinodular goiter without any preoperative suspicion of malignancy, history of familial thyroid can...

متن کامل

Efficacy of LigaSure® Use during Total Thyroidectomy for Multinodular Goitre: A Prospective Randomized Study

Background: Thyroid surgery commonly carried out by surgeons is generally achieved by threadtying technique which lengthens the operation period. Therefore, new technologies are needed to decrease the operation time without increasing complications. LigaSure® PreciseTM is a new vascular sealing system with an integrated active feedback control. The aims of the present study are to assess the ef...

متن کامل

A Novel Germline Mutation of KEAP1 (R483H) Associated with a Non-Toxic Multinodular Goiter

BACKGROUND A germline mutation of KEAP1 gene was reported as a novel genetic abnormality associated with familial multinodular goiter. That report was limited, and the pathogenic features were not well established. PATIENT FINDINGS We report a 47-year-old Japanese woman who presented with hyperthyroidism and a large multinodular goiter. The family history was notable for a paternal history of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2012