Buflomedil interference with the monoclonal EMIT d.a.u. amphetamine/methamphetamine immunoassay.
نویسندگان
چکیده
The interference of buflomedil with the monoclonal and polyclonal EMIT d.a.u. amphetamine immunoassays was investigated. Urine samples collected from 20 patients taking 600 mg of buflomedil daily gave false positive results with the monoclonal EMIT d.a.u. assay, as did urine specimens collected 2 hours after the first oral dose of buflomedil. Conversely, no false positive results occurred with the polyclonal EMIT d.a.u. amphetamine assay. Urine samples with buflomedil added at concentrations greater than 100 mg/l gave false positive results with the monoclonal immunoassay. Buflomedil concentrations found in the patient urines (56-400 mg/l) failed to correlate to EMIT assay responses: this result suggests that one or more buflomedil metabolites, besides the unchanged drug, probably interfere in the monoclonal EMIT d.a.u. assay.
منابع مشابه
Evaluation of Immunoassays for the Determination of MDMA and Cannabinoids in Urine Samples
Methylenedioxymethamphetamine (MDMA) is structurally related to methamphetamine (MA). There are many different commercially available immunoassay (IA) reagents for the initial screening of amphetamine and/or methamphetamine. These reagents may be employed to detect MDA/MDMA in urine samples. In order to select a suitable reagent for the initial screening of MDMA in urine samples, we evaluated 7...
متن کاملAnalytical Performance Evaluation of EMIT#{174} II Monoclonal Amphetamine/ Methamphetamine Assay: More Specificitythan EMIT#{174} d.a.u.TMMonoclonal Amphetamine/Methamphetamine Assay
We evaluated a new EMIT#{174} II monoclonal amphetamine! methamphetamine assay for screening human urine by comparing itwith the EMIT#{174} d.a.u. monoclonal amphetamine/methamphetamine assay and a fluorescence polarization assay. The EMIT II assay has a cutoff of 1 mg!L d-methamphetamine. The EMIT II and EMIT d.a.u. assays were run on a BM/Hitachi 704 analyzer; for the fluorescence polarizatio...
متن کاملIntrasubject variation of creatinine and specific gravity measurements in consecutive urine specimens of heroin users.
116 CLINICAL CHEMISTRY, Vol. 41, No. 1, 1995 drugs in full-scan and selected.ion monitoring modes. Clin Chem 1994;40:216-20. 2. Doolittle MH, Lincoln K, Graves SW. Unexplained increase in serum digoxin: case report. Clin Chem 1994;40:487-92. 3. Critchfield GC, Wilkins DG, Loughmiller DL, Davis BW, Rollins DE. Antibody-mediated interference of a homogeneous immunoassay. J Anal Toxicol 1993;17:69...
متن کاملComparison of RapiTest with Emit d.a.u. and GC-MS for the analysis of drugs in urine.
Results obtained with RapiTest THC (One Step delta 9-Tetrahydrocannabinol Test), RapiTest MOP (One Step Morphine Test), RapiTest MET (One Step Methamphetamine Test), and RapiTest COC (One Step Cocaine Test) were compared with the results obtained with Emit d.a.u. and with gas chromatographic-mass spectrometric (GC-MS) methods. In all, 81 urine samples taken from specimens submitted for routine ...
متن کاملComparison of the sensitivity and specificity of six immunoassays for the detection of amphetamines in urine.
We analyzed 225 urine samples with FPIA (Abbott Amphetamine/Methamphetamine II on ADx and AxSYM), EMIT (Emit II Plus Monoclonal Amphetamine/Metamphetamine assay and EMIT II Plus Amphetamines assay, EMIT N), and KIMS (standard protocol and MDMA protocol, KIMS and KIMS X, respectively) immunoassays and compared their sensitivity and specificity. All assays were calibrated and used semi-quantitati...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- European journal of clinical chemistry and clinical biochemistry : journal of the Forum of European Clinical Chemistry Societies
دوره 35 5 شماره
صفحات -
تاریخ انتشار 1997