Agreement of left ventricular mass in steady state free precession and delayed enhancement MR images: implications for quantification of fibrosis in congenital and ischemic heart disease
نویسندگان
چکیده
BACKGROUND Left ventricular mass (LVM) is used when expressing infarct or fibrosis as a percentage of the left ventricle (LV). Quantification of LVM is interchangeably carried out in cine steady state free precession (SSFP) and delayed enhancement (DE) magnetic resonance imaging (MRI). However, these techniques may yield different LVM. Therefore, the aim of the study was to compare LVM determined by SSFP and DE MRI in patients and determine the agreement with these sequences with ex vivo data in an experimental animal model. METHODS Ethics committees approved human and animal studies. Informed written consent was obtained from all patients. SSFP and DE images were acquired in 60 patients (20 with infarction, 20 without infarction and 20 pediatric patients). Ex vivo MRI was used as reference method for LVM in 19 pigs and compared to in vivo SSFP and DE. RESULTS LVM was greater in SSFP than in DE (p < 0.001) with a bias of 5.0 +/- 6.7% in humans (r2 = 0.98), and a bias of 7.3 +/- 6.7% (p < 0.001) in pigs (r2 = 0.83). Bias for SSFP and DE images compared to ex vivo LVM was -0.2 +/- 9.0% and -7.7 +/- 8.5% respectively. CONCLUSIONS LVM was higher when measured with SSFP compared to DE. Thus, the percentage infarction of the LV will differ if SSFP or DE is used to determine LVM. There was no significant difference between SSFP and ex vivo LVM suggesting that SSFP is more accurate for LVM quantification. To avoid intrinsic error due to the differences between the sequences, we suggest using DE when expressing infarct as a percentage of LVM.
منابع مشابه
Comparison the Accuracy of Fetal Brain Extraction from T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR Image with T2-True Fast Imaging with Steady State Free Precession (TRUFI) MR Image by Level Set Algorithm
Background Access to appropriate images of fetal brain can greatly assist to diagnose of probable abnormalities. The aim of this study was to compare the suitability of T2-True Fast Imaging with Steady State Free Precession (T2-TRUFI), and T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (T2- HASTE( magnetic resonance imaging (MRI) to extract the fetal brain using the level set algorithm...
متن کاملThe Correlation between Left and Right Ventricular Ejection Fractions in Patients with Ischemic Heart Disease, Documented by Cardiac Magnetic Resonance Imaging
Introduction: The correlation between right and left ventricular ejection fractions (RVEF and LVEF, respectively) has been studied in only a small number of patients with a marked decrease in RVEF and LVEF. The aim of the present study was to compare LVEF and RVEF in patients with ischemic heart disease. RVEF and LVEF were measured by Cardiovascular Magnetic Resonance (CMR) imaging. Materials a...
متن کاملCan chronotropic incompetence predict life-threatening ventricular arrhythmias in patients with stable ischemic heart disease?
Background: Chronotropic incompetence has prognostic value of all-cause and cardiovascular mortality in both patients with asymptomatic and symptomatic ischemic heart disease (IHD), regardless of traditional risk factors. The aim of this study was to investigate the relationship between chronotropic response during exercise test and the development of ventricular arrhythmias. Methods: 153 pati...
متن کاملCMR measurements of myocardial infarct heterogeneity using MCLE and IR-FGRE: correlation with arrhythmia inducibility and severe ICD events in patients with ischemic heart disease
Background In addition to measures of left ventricular ejection fraction (LVEF) and clinical staging of heart failure, myocardial infarct (MI) heterogeneity including MI and periinfarct gray-zone (GZ) has the potential to predict the occurrence of inducible sustained ventricular arrhythmia (VA) and spontaneous VA events after implantation of implantable defibrillator (ICD) in patients with isch...
متن کاملQuantitative Evaluation of the Amount of Delayed Myocardial Enhancement as a Predictor of Systolic Dysfunction
30 patients with delayed contrast enhancement in patterns suggestive of myocardial infarctions were reviewed. Infarct mass was quantitatively measured using short axis images obtained in the delayed phase of gadopentetate administration. Left ventricular mass and ejection fraction were measured using short axis, steady state free precession images. A relationship is drawn between increased mass...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 10 شماره
صفحات -
تاریخ انتشار 2010