Modified spectrum autointerferometric correlation (MOSAIC) for single-shot pulse characterization.

نویسندگان

  • Daniel A Bender
  • Mansoor Sheik-Bahae
چکیده

A method for generation of the modified spectrum autointerferometric correlation that allows single-shot pulse characterization is demonstrated. A sensitive graphical representation of the ultrashort pulse phase quality is introduced that delineates the difference between the presence of temporal and spectral phase distortions. Using these schemes, full-field reconstruction of ultrashort laser pulses is obtained in real time using an efficient iterative technique.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Complementary ultrashort laser pulse characterization using MOSAIC and SHG FROG.

A new (to our knowledge) method for generating the modified spectrum autointerferometric correlation (MOSAIC) trace from the second-harmonic generation frequency-resolved optical gating (SHG FROG) dataset is shown. Examples are presented illustrating enhanced visual sensitivity, applicability, and complementary qualitative pulse characterization using SHG FROG.

متن کامل

Ultrashort laser pulse characterization using modified spectrum auto-interferometric correlation (MOSAIC).

Sensitive, real-time chirp and spectral phase diagnostics along with full field reconstruction of femtosecond laser pulses are performed using a single rapid-scan interferometric autocorrelator. Through the use of phase retrieval error maps, ambiguities in pulse retrievals based on the pulse spectrum and various forms of MOSAIC traces are discussed. We show second-order autocorrelations can int...

متن کامل

General ultrafast pulse measurement using the cross-correlation single-shot sonogram technique.

The cross-correlation single-shot sonogram technique offers exact pulse measurement and real-time pulse monitoring via an intuitive time-frequency trace whose shape and orientation directly indicate the spectral chirp of an ultrashort laser pulse. We demonstrate an algorithm that solves a fundamental limitation of the cross-correlation sonogram method, namely, that the time-gating operation is ...

متن کامل

A compact and versatile tender X-ray single-shot spectrometer for online XFEL diagnostics

One of the remaining challenges for accurate photon diagnostics at X-ray free-electron lasers (FELs) is the shot-to-shot, non-destructive, high-resolution characterization of the FEL pulse spectrum at photon energies between 2 keV and 4 keV, the so-called tender X-ray range. Here, a spectrometer setup is reported, based on the von Hamos geometry and using elastic scattering as a fingerprint of ...

متن کامل

Single Shot Longitudinal Bunch Profile Measurements at Flash Using Electro-optic Techniques

For the high-gain operation of a SASE FEL, extremely short electron bunches are essential to generate sufficiently high peak currents. At the superconducting linac of FLASH at DESY, we have installed an electro-optic experiment with temporal decoding and spectral decoding to probe the time structure of the electric field of single sub-200 fs electron bunches. In this technique, the fieldinduced...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics letters

دوره 32 19  شماره 

صفحات  -

تاریخ انتشار 2007