Reproducibility of a triaxial seismic accelerometer (DynaPort).

نویسندگان

  • Vincent T Van Hees
  • Sander M Slootmaker
  • Gert De Groot
  • Willem Van Mechelen
  • Rob C Van Lummel
چکیده

PURPOSE To examine the reproducibility of a triaxial seismic accelerometer under controlled conditions and real-life conditions. METHODS Instrumental reproducibility was examined using a shaker device. The accelerometers (DynaPort MiniMod; McRoberts B.V., The Hague, The Netherlands) were shaken at four frequencies (0.8, 2.1, 3.6, and 4.6 Hz) in x- and y-directions. The magnitude of acceleration ranged from 0 to 1.277g. Additionally, reproducibility under real-life conditions was examined in 55 adolescents (12-17 yr), with the accelerometer attached to the lower back. Each subject walked four short walking trials on level ground at preferred speed. To make this setting meet real-life conditions, we detached and reattached the accelerometer between trials 2 and 3. Detachment of accelerometer between trials 2 and 3 was done by either the same researcher or different researchers (four in total). Intra- and interobserver reproducibility were calculated. RESULTS Intra- and interinstrumental intraclass correlation coefficients (ICC) were 0.99 for both x- and y-directions. The intrainstrumental coefficients of variance (CoV) were lower than 1.13%. The interinstrumental CoV were lower than 1.37%. Intraobserver ICC was 0.97, and interobserver ICC was 0.88. CONCLUSION The reproducibility of the accelerometer is high under the controlled conditions of a shaker device and in walking at preferred speed.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation of the triaxial accelerometer for the evaluation of physical activity in Japanese patients with COPD.

OBJECTIVE The quantification of physical activity is useful for the management of chronic obstructive pulmonary disease (COPD) but has not been fully established yet. The DynaPort Activity Monitor(®) (DAM), a triaxial accelerometer is the only well validated accelerometer in Caucasians but it has not been validated in Japanese COPD patients. We initially evaluated the reproducibility of the DAM...

متن کامل

Validity of DynaPort GaitMonitor for assessment of spatiotemporal parameters in amputee gait.

Accelerometry can be used to objectively assess the walking ability of people with a lower-limb prosthesis inside and outside the laboratory setting. In this study, the validity of the DynaPort GaitMonitor software (McRoberts, The Hague, the Netherlands) for assessing spatiotemporal parameters of amputee gait was evaluated. Fourteen subjects with a lower-limb prosthesis walked on a straight lev...

متن کامل

Physical Activity in Hemodialysis Patients Measured by Triaxial Accelerometer

Different factors can contribute to a sedentary lifestyle among hemodialysis (HD) patients, including the period they spend on dialysis. The aim of this study was to evaluate characteristics of physical activities in daily life in this population by using an accurate triaxial accelerometer and to correlate these characteristics with physiological variables. Nineteen HD patients were evaluated u...

متن کامل

Estimating activity-related energy expenditure under sedentary conditions using a tri-axial seismic accelerometer.

Activity-related energy expenditure (AEE) is difficult to quantify, especially under sedentary conditions. Here, a model was developed using the detected type of physical activity (PA) and movement intensity (MI), based on a tri-axial seismic accelerometer (DynaPort MiniMod; McRoberts B.V., The Hague, the Netherlands), with energy expenditure for PA as a reference. The relation between AEE (J/m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Medicine and science in sports and exercise

دوره 41 4  شماره 

صفحات  -

تاریخ انتشار 2009