Comparing ambient, air-convection, and fluid-convection heating techniques in treating hypothermic burn patients, a clinical RCT

نویسندگان

  • Britt-Marie Kjellman
  • Mats Fredrikson
  • Gunilla Glad-Mattsson
  • Folke Sjöberg
  • Fredrik RM Huss
چکیده

BACKGROUND Hypothermia in burns is common and increases morbidity and mortality. Several methods are available to reach and maintain normal core body temperature, but have not yet been evaluated in critical care for burned patients. Our unit's ordinary technique for controlling body temperature (Bair Hugger®+ radiator ceiling + bed warmer + Hotline®) has many drawbacks e.g.; slow and the working environment is hampered.The aim of this study was to compare our ordinary heating technique with newly-developed methods: the Allon™2001 Thermowrap (a temperature regulating water-mattress), and Warmcloud (a temperature regulating air-mattress). METHODS Ten consecutive burned patients (> 20% total burned surface area and a core temperature < 36.0°C) were included in this prospective, randomised, comparative study. Patients were randomly exposed to 3 heating methods. Each treatment/measuring-cycle lasted for 6 hours. Each heating method was assessed for 2 hours according to a randomised timetable. Core temperature was measured using an indwelling (bladder) thermistor. Paired t-tests were used to assess the significance of differences between the treatments within the patients. ANOVA was used to assess the differences in temperature from the first to the last measurement among all treatments. Three-way ANOVA with the Tukey HSD post hoc test and a repeated measures ANOVA was used in the same manner, but included information about patients and treatment/measuring-cycles to control for potential confounding. Data are presented as mean (SD) and (range). Probabilities of less than 0.05 were accepted as significant. RESULTS The mean increase, 1.4 (SD 0.6°C; range 0.6-2.6°C) in core temperature/treatment/measuring-cycle highly significantly favoured the Allon™2001 Thermowrap in contrast to the conventional method 0.2 (0.6)°C (range -1.2 to 1.5°C) and the Warmcloud 0.3 (0.4)°C (range -0.4 to 0.9°C). The procedures for using the Allon™2001 Thermowrap were experienced to be more comfortable and straightforward than the conventional method or the Warmcloud. CONCLUSIONS The Allon™2001 Thermowrap was more effective than the Warmcloud or the conventional method in controlling patients' temperatures.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Free convection in a 3D chamber with local cooling and heating

This paper modeled heating air of a room through examining free convection in a 3D chamber. The chamber had cold and hot sources with Tc and Th temperatures, respectively. Its other walls were adiabatic. This study aimed at predicting effect of temperature difference, displacement of hot and cold sources and their aspect ratio on flow field, temperature and heat transfer rate. To conduct the st...

متن کامل

Natural Convection from a Helical Heating Coil to the Surrounding Fluid.

An experimental study is reported on natural convection heat transfer from a helical heating coil to the surrounding fluid. The coil is heated electrically and the surrounding fluid is selected to be water. The range of parameters are: Rayleigh number, 879 ?£ Ra ?£ 780168, Prandtl number, 4.22 ?£ Pr ?£ 10.02, dimensionless coil diameter,7.69 ?£ Dave /d ?£ 10.77, number of coil rings, 2 ?£ N ?£ ...

متن کامل

The Optimal Design of Heat Sinks: A Review

Heat sinks are used in industrial equipment to dissipate the excess heat from their heat-generating parts to the ambient. In the last few years, efforts on manufacturing electronic or mechanical devices with less weight, space, and lower cost were spent. Heat dissipation from the heat sink is stalling a big problem which many researchers are trying to solve. The aim of this study is to brief th...

متن کامل

Magnetohydrodynamic mixed convection effects on the removal process of fluid particles from an open cavity in a horizontal channel

This paper presents the results of a numerical study on the heat transfer performance and the removal process of fluid particles under the influence of magnetohydrodynamic mixed convection in a horizontal channel with an open cavity. The bottom wall of the cavity is heated at a constant temperature (Th) while the top wall of the channel is maintained at a relatively low temperature (Tc). Air wi...

متن کامل

Airflow and Heat Transfer in the Slot-Vented Room with Radiant Floor Heating Unit

Radiant floor heating has received increasing attention due to its diverse advantages, especially the energy saving as compared to the conventional dwelling heating system. This paper presents a numerical investigation of airflow and heat transfer in the slot-vented room with the radiant floor heating unit. Combination of fluid convection and thermal radiation has been implemented through the t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2011