A novel hypothermic machine perfusion system using a LifePort Kidney Transporter for the preservation of rat liver
نویسندگان
چکیده
The protective mechanisms for liver preservation associated with hypothermic machine perfusion (HMP) remain unclear. However, the lack of a common and portable HMP system for rat livers limits the study of HMP. The present study aimed to develop a novel, modified HMP system using a LifePort Kidney Transporter for preserving rat livers. A simple 'Y' shunt combined with a pressoreceptor for flow and pressure regulation was adapted to perfuse rat livers via the portal vein continuously using a LifePort Kidney Transporter under its 'prime mode' setting. An electronic scale was installed under the liver container to calculate the portal inflow according to the association with weight, density and volume of the perfusate. A total of 10 rat livers underwent 6 h of HMP using histidine-tryptophan-ketoglutarate solution enriched with acridine orange (AO) and propidium iodide (PI). The perfusion status of HMP was assessed by comparison of AO+PI-positive cell count in core region (CR) and peripheral region (PR) of rat liver under fluorescence microscopy. The dynamics (inflow, pressure and intrahepatic resistance of perfusion) were assessed to identify whether this system met the demands for HMP of rat livers. Biochemical [alanine transaminase (ALT), lactate dehydrogenase (LDH) and endothelin levels] and histological parameters (sinusoidal dilatation, endothelial cell detachment and vacuolization) were measured to determine cellular damage associated with HMP. No significant difference was observed between the CR and PR according to the comparison of the AO+PI-positive cell count, which indicated that complete perfusion was achieved. Intrahepatic resistance significantly decreased during the initial 3 h of HMP (P<0.01), but remained stable during the final 3 h. ALT and LDH levels significantly increased over the 6 h HMP duration: ALT (0 h, 42.67±5.81 U/l; 3 h, 90.67±6.74 U/l; 6 h, 164.33±7.31 U/l; P<0.01) and LDH (0 h, 492.90±90.20 U/l; 3 h, 973.53±97.4; 6 h, 1,843.40±85.78 U/l; P<0.01) However, the levels of endothelin and oxygen consumption were constant throughout HMP. Furthermore, histological analysis indicated sinusoidal dilation was significantly increased in the post-HMP group compared with the pre-HMP group (P<0.01); however, no other significant differences were observed. Combined with the results of ATP test (640.64±29.46 nmol/l) and bile production (4.88±0.69 µl/h/g of liver) at the end of HMP, the present results demonstrated minimal cellular injury associated with HMP while retaining the dependability and portability of the LifePort Kidney Transporter, which suggests the modified HMP system met the demands required and may be suitable for rat liver preservation.
منابع مشابه
Hypothermic Machine Perfusion Preservation of the DCD Kidney: Machine Effects
Purpose. Kidneys from DCD donors represent a significant pool, but preservation problems exist. The study objective was to test the importance of machine type for hypothermic preservation of DCD kidneys. Methods. Adult Beagle dog kidneys underwent 45 minutes of warm in situ ischemia followed by hypothermic perfusion for 24 hours (Belzer-MPS Solution) on either an ORS LifePort or a Waters RM3 us...
متن کاملHypothermic Perfusion of Pancreas: Emphasis on Preservation Prior to Islet Isolation
Procurement and preservation of pancreata is important for both segmental gland transplantation and islet isolation as a prelude to islet transplantation as a potentially new option for the treatment of Type I diabetes mellitus. The methods described here focus on the latter application and apply the LifePort kidney platform transporter to prolonged pancreas hypothermic machine perfusion (HMP)....
متن کاملMetabolomic Perfusate Analysis during Kidney Machine Perfusion: The Pig Provides an Appropriate Model for Human Studies
INTRODUCTION Hypothermic machine perfusion offers great promise in kidney transplantation and experimental studies are needed to establish the optimal conditions for this to occur. Pig kidneys are considered to be a good model for this purpose and share many properties with human organs. However it is not established whether the metabolism of pig kidneys in such hypothermic hypoxic conditions i...
متن کاملThe effectiveness and cost-effectiveness of methods of storing donated kidneys from deceased donors: a systematic review and economic model.
OBJECTIVE To review the evidence for the effectiveness and cost-effectiveness of storing kidneys from deceased donors prior to transplantation, using cold static storage solutions or pulsatile hypothermic machine perfusion. DATA SOURCES Electronic databases were searched in January 2008 and updated in May 2008 for systematic reviews and/or meta-analyses, randomised controlled trials (RCTs), o...
متن کاملHypothermic Machine Preservation of the Liver: State of the Art
Purpose of Review In this review, we highlight which livers may benefit from additional treatment before implantation and describe the concept of hypothermic machine liver perfusion. Furthermore, we explain why cold oxygenated perfusion concepts could potentially lead to a breakthrough in this challenging field of transplantation. Accordingly, we summarize recent clinical applications of differ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 15 شماره
صفحات -