Transapical aortic valve implantation using a Symetis Acurate self-expandable bioprosthesis: initial outcomes of 10 patients

نویسندگان

  • Marcin Misterski
  • Mateusz Puślecki
  • Marek Grygier
  • Anna Olasińska-Wiśniewska
  • Maciej Lesiak
  • Aleksander Araszkiewicz
  • Barłomiej Perek
  • Aneta Choręziak
  • Jacek Lindner
  • Anna Komosa
  • Piotr Buczkowski
  • Marcin Ligowski
  • Sławomir Katarzyński
  • Marek Jemielity
چکیده

INTRODUCTION Transapical aortic valve implantation (TA-AVI) has been widely introduced for treatment of patients with severe aortic stenosis in the last decade. Here we report our first clinical experience with 10 patients using the second-generation transapical Symetis Acurate TA aortic valve designed for transapical implantation. AIM To evaluate the results of transapical access in transcatheter aortic valve implantation (TAVI) among patients with unsuitable vascular access. MATERIAL AND METHODS All patients had been assessed by a local heart team and were disqualified from surgical aortic valve replacement (AVR) and the transfemoral TAVI approach. Mean age was 75.4 ±3.9 years (range: 68-80), with 20% being female. Logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation) and STS (Society of Thoracic Surgeons) were 15.4 ±8.9% and 20.5 ±4.5%, respectively. RESULTS All implantations were performed successfully in the intra-annular and subcoronary position. There were no conversions to surgical AVR. All patients survived 30-day follow-up. No strokes or transient ischemic attacks were reported. There was no need for pacemaker implantation and none of the patients demonstrated moderate or significant paravalvular leakage. The mean aortic gradients improved significantly from a baseline of 57.0 ±19.2 mm Hg to a 30-day value of 14.2 ±4.1 mm Hg. CONCLUSIONS Our initial clinical results indicate satisfactory functionality in patients after trans-apical implantation of the Symetis Acurate aortic valve. The procedure of implantation seems to be straightforward and may be considered in patients in whom a transfemoral approach is not a good option.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Self-Expanding Symetis Acurate Does Not Increase Cerebral Microembolic Load When Compared to the Balloon-Expandable Edwards Sapien Prosthesis: A Transcranial Doppler Study in Patients Undergoing Transapical Aortic Valve Implantation

OBJECTIVES The aim of this study was to quantify potential differences in count, frequency and pattern of high-intensity transient signals (HITS) during transapical transcatheter aortic valve implantation (TA-TAVI), by comparing the Symetis Acurate TA (SA) with the balloon-expandable Edwards Sapien XT (ES) system. BACKGROUND Recently, the Symetis Acurate TA revalving system has been introduce...

متن کامل

Transapical aortic valve implantation using a new self-expandable bioprosthesis (ACURATE TA™): 6-month outcomes.

OBJECTIVES The ACURATE TA(™) Aortic Bioprosthesis and Delivery System (Symetis S.A., Ecublens, Switzerland) is a new transcatheter aortic valve designed for transapical implantation. The six-month results from the completed first-in-man study are reported. METHODS The Symetis ACURATE TA(™) is composed of a porcine biological tissue valve attached to a self-expandable nitinol stent. It allows ...

متن کامل

Comparison of two valve systems for transapical aortic valve implantation: a propensity score-matched analysis.

OBJECTIVES Several alternative transapical (TA) aortic prostheses for aortic valve implantation (AVI) have recently become available. Data directly comparing the performance of these different TA-AVI valves, however, are sparse. Therefore, we sought to analyse the performance of the better-established balloon-expandable SAPIEN XT™ valve system, and compare it with the recently approved self-exp...

متن کامل

Symetis Acurate Transapical Aortic Valve: the initial experience with a second generation of transcatheter aortic valve replacement device.

BACKGROUND Transcatheter aortic valve replacement (TAVR) has proven to be a valuable alternative to conventional surgical aortic valve replacement in high risk and surgically in operable patients who suffer from severe symptomatic aortic stenosis. However, a significant number of complications, associated with both the learning curve and device specificity, have required attention and subsequen...

متن کامل

Transapical implantation of a self-expanding aortic valve bioprosthesis--animal feasibility study.

BACKGROUND Severe peripheral arterial disease may pose a limitation to the applicability of trans-arterial aortic valve implantation in patients who are otherwise candidates. For this reason, transapical aortic valve implantation has been proposed as a possible alternative. OBJECTIVE To evaluate the acute safety and performance of a specially designed delivery system, the CoreValve Tranzap de...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017