Radiometric detection of bacteremia in neonates.

نویسندگان

  • R M Bannatyne
  • N Harnett
چکیده

The predicted prevalence of false positive blood cultures due to hyperactive neonatal blood cells in a radiometric detection system was confirmed. Suppression of this blood background radioactivity in the system was achieved by using a hypertonic medium containing 10% sucrose. The radiometric system produced accurate results as fast as the conventional blood culturing method, saved labor and minimized the recovery of extraneous contaminants.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiometric method for detection of bacteremia.

A study was performed with simulated blood cultures to evaluate the production of (14)CO(2) as an index of bacterial growth. With a range of inoculum sizes from 4 to 4,250 colony-forming units, it was not possible to detect (14)CO(2) within 6 hr after inoculation in 59 separate experiments. In a limited trial with patients' blood cultures, the radiometric method failed to provide any earlier ev...

متن کامل

Detection of bacteremia in patients receiving antimicrobial therapy: an evaluation of the antimicrobial removal device and 16B medium.

A total of 1097 blood specimens obtained from patients receiving antibacterial antimicrobial agents were processed by three blood culture systems: standard aerobic and anaerobic radiometric media, resin-containing radiometric medium (16B; Johnston Laboratories, Cockeysville, Md.), and aerobic and anaerobic radiometric media inoculated with blood processed in an Antimicrobial Removal Device (Mar...

متن کامل

Laboratory experience with radiometric detection of bacteremia with three culture media.

In two long-term studies, the BACTEC radiometric system for detection of bacteremia was evaluated with three culture media each: (i) BACTEC media 6A (for aerobes) and 7B (for anaerobes) plus a thioglycolate medium and (ii) BACTEC media 6A, 7B, and 8A (hypertonic). In study 1, clinically significant isolates were identified in 1,873 (13.9%) of 13,432 blood cultures with all three media. The thio...

متن کامل

Radiometric detection of bacteremia: requirement for terminal subcultures.

A radiometric procedure for rapid detection of bacteria in clinical blood specimens was utilized over a period of 1 year in this laboratory. Although in initial studies it was felt that all positive bacteremias would be detected by radiometric examination of cultures for 14CO2 evolution over a 7-day period, we found in the present study that a significant number of bacteria were not detected, e...

متن کامل

Controlled evaluation of supplemented peptone and Bactec blood culture broths for the detection of bacteremia and fungemia.

Comparison of conventional blood culture media with newer formulations of Bactec media for radiometric detection are lacking. Therefore, we compared the yield and speed of detection of clinically important microorganisms with supplemented peptone broth (SPB) and Bactec aerobic (6B) and anaerobic (7C or 7D) broths in 7,627 blood samples from adult patients. Acridine orange stains from SPB, radio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied microbiology

دوره 27 6  شماره 

صفحات  -

تاریخ انتشار 1974