A comparison of perimetric results with the Medmont and Humphrey perimeters.
نویسندگان
چکیده
BACKGROUND The Humphrey field analyser (HFA), Humphrey-Zeiss frequency doubling perimeter, and the Medmont automated perimeter (MAP) are three commonly used automated perimeters with threshold achromatic methodologies. Visual field loss may be detected earlier with strategies that target cell lines with reduced redundancy or which suffer selective damage. METHOD To compare these three perimeters, 63 subjects who were glaucoma suspects, ocular hypertensives, glaucoma patients, or normal controls were recruited selectively. All subjects underwent testing using MAP central threshold, MAP flicker perimetry, HFA full threshold, HFA SITA perimetry, HFA short wavelength perimetry (SWAP), and frequency doubling perimetry (FDP). After visual field testing, equivalent tests were compared: MAP central threshold with HFA full threshold and HFA SITA perimetry; Medmont flicker perimetry with HFA SWAP and FDP. RESULTS On analysis of the MAP central threshold a kappa statistic and an area under the receiver operator curve (AUC) of 0.90 and 0.94, respectively, were found compared with HFA full threshold strategies, and 0.87 and 0.92 respectively, compared with HFA SITA. For MAP flicker a kappa statistic and an AUC of 0.65 and 0.81, respectively, were found compared with HFA SWAP and 0.87 and 0.96, respectively, compared with FDP. A quadrant analysis and comparison of mean defect between tests was also highly significant. CONCLUSION Medmont and Humphrey perimeters correlated well; both may be used for clinical and research purposes with similar confidence.
منابع مشابه
SCIENTIFIC REPORT A comparison of global indices between the Medmont Automated Perimeter and the Humphrey Field Analyzer
Background: Two commonly used perimeters in Australia are the Humphrey Field Analyzer II (HFA) and the Medmont Automated Perimeter (MAP). Each device describes the visual field in terms of numerical values called global indices; however, these values are not interchangeable between devices. This study was designed to directly compare the global indices of HFA and MAP visual fields. Methods: 63 ...
متن کاملA comparison of global indices between the Medmont Automated Perimeter and the Humphrey Field Analyzer.
BACKGROUND Two commonly used perimeters in Australia are the Humphrey Field Analyzer II (HFA) and the Medmont Automated Perimeter (MAP). Each device describes the visual field in terms of numerical values called global indices; however, these values are not interchangeable between devices. This study was designed to directly compare the global indices of HFA and MAP visual fields. METHODS 63 ...
متن کاملAnatomy of a supergroup: does a criterion of normal perimetric performance generate a supernormal population?
PURPOSE To interpret individual results from automated perimeters, a normative database must be developed. Typically, a set of criteria determines those subjects that may be included in the database. This study examined whether a criterion of normal performance on an established perimeter generates a subgroup with supernormal perimetric performance. METHODS The right-eye perimetric results of...
متن کاملPerimetry Comparisons for Octopus G Top and Dynamic Programmes versus Humphrey 24-2 SITA Fast and SITA Standard Programmes
Aims: Previous comparisons of Octopus and Humphrey threshold programmes have shown differences, particularly for depth of defects. Recent developments have altered the Octopus background illumination. Thus, we sought to determine the subsequent extent of differences in results from commonly used central static programmes using Octopus and Humphrey perimeters. Study Design: Diagnostic accuracy s...
متن کاملA comparison of tangent screen, goldmann, and humphrey perimetry in the detection and localization of occipital lesions.
OBJECTIVE To compare manual kinetic perimetry with tangent screen and Goldmann techniques and automated static perimetry with the Humphrey Field Analyzer in the detection and localization of occipital lobe lesions. DESIGN Prospective consecutive comparative case series. PARTICIPANTS Twelve patients with well-defined occipital lobe infarcts on magnetic resonance (MR) imaging were studied. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The British journal of ophthalmology
دوره 87 6 شماره
صفحات -
تاریخ انتشار 2003