Determining time resolution of microchannel plate detectors for electron time-of-flight spectrometers.

نویسندگان

  • Qi Zhang
  • Kun Zhao
  • Zenghu Chang
چکیده

The temporal resolution of a 40 mm diameter chevron microchannel plate (MCP) detector followed by a constant fraction discriminator and a time-to-digital converter was determined by using the third order harmonic of 25 fs Ti:sapphire laser pulses. The resolution was found to deteriorate from 200 to 300 ps as the total voltage applied on the two MCPs increased from 1600 to 2000 V. This was likely due to a partial saturation of the MCP and/or the constant fraction discriminator working with signals beyond its optimum range of pulse width and shape.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection Techniques for On-Line Mass Determination with Penning Traps

A Penning trap mass spectrometer is a well established instrument for the precise mass determination of both, stable and short-lived nuclides. For this purpose two different concepts are employed. Masses of stable species are mostly determined by the non-destructive detection of image currents induced in the trap electrodes and a subsequent Fourier transformation (FT). For short-lived nuclides ...

متن کامل

Miniature time-of-flight mass spectrometer using a flexible circuitboard reflector

An innovative design for a miniature time-of-flight mass spectrometer has been developed employing several newly designed components. These include: (1) a gridless, focusing ion source allowing for the use of very high extraction energies in a maintenance-free design, (2) a new method of construction for an ion reflector using rolled flexible circuitboard material, and (3) an improved center-ho...

متن کامل

Beam test of a Time-of-Flight detector prototype

We report on results of a Time-of-Flight, TOF, counter prototype in beam tests at SLAC and Fermilab. Using two identical 64-pixel Photonis Microchannel Plate Photomultipliers, MCP-PMTs, to provide start and stop signals, each having a 1 cm-long quartz Cherenkov radiator, we have achieved a timing resolution of σSingle_detector ~14 ps. To be published in Nucl. Instr.& Methods ——— • Manuscript re...

متن کامل

Microchannel plate cross-strip detectors with high spatial and temporal resolution.

The cross-strip imaging readout employs charge division, and centroiding, of microchannel plate charge signals detected on two orthogonal layers of sense strips to encode event X-Y positions and times. We have developed cross-strip detectors and fully parallel channel position encoding electronics. The front-end amplifiers utilize two 32-channel pre-amplifier ASICs that send signals to a full 6...

متن کامل

Improving the resolution in soft X-ray emission spectrometers through photon-counting using an Electron Multiplying CCD

In 2007, a study of back-illuminated Charge-Coupled Devices (CCDs) for soft Xray photon detection demonstrated the improvements that could be brought over more traditional micro-channel plate detectors for X-ray spectrometers based on diffraction gratings and position sensitive detectors. Whilst the spatial resolution was reported to be improved dramatically, an intrinsic limit of approximately...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 81 7  شماره 

صفحات  -

تاریخ انتشار 2010