Performance Comparison of Temperature and Humidity Independent Control Air-conditioning System and the Conventional Air-conditioning System

نویسندگان

  • Haiqiang Zhang
  • Xiaohua Liu
  • Yi Jiang
چکیده

This article introduces two system models to simulate the energy performance of the temperature and humidity independent control air-conditioning system (THICS) and the conventional airconditioning system (CAS). The energy performance comparison includes three parts of cooling resource, transportation system and terminal devices. A typical office building with these two different systems is numerically analyzed. Beijing and Guangzhou, two major cities in China, are chosen, which lay in temperate zone and tropical zone respectively. In Beijing office building, the Energy Efficient Ratio (EER) of THICS is 4.5, while which of CAS is 3.6. In Guangzhou office building, the EER of THICS is 4.5, while which of CAS is 3.4.The energy efficiency of THICS is higher than that of CAS and THICS can save 20%~30% energy consumption compared with the CAS. In detail, cooling resource accounts for the biggest part of the energy-saved.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Designing Fuzzy Controller for Air Conditioning Systems in order to Save Energy Consumption and Provide Optimal Conditions in Closed Environments (Indoors)

Today air conditioning systems have been considered by all people as one of welfarerequirements in buildings and closed environments. Since a considerable part of energy lossoccurs in ordinary modern systems, new strategies and solutions are developed in the field inorder to save amount of energy consumption and observe environmental considerations. Fuzzycontrol is one of these methods which pr...

متن کامل

Thermal modeling of mini-channel and laminated Types evaporator in mobile air conditioning system

In this paper, mini-channel type evaporator which is new in mobile air conditioning (MAC) or automotive air conditioning (AAC) systems is thermally modeled. The performance of mini-channel evaporator is also compared with the laminated evaporator which is being currently used in automotive industries. The mini-channel evaporator was constructed of two rows of parallel flow mini-channel tubes...

متن کامل

Fully Fresh Air Air-conditioning System Equipped with Double Heat Pipe Based Heat Recovery Technology

The using of double heat pipe based heat exchanger (HPHX) in a conventional fully fresh air air-conditioning (AC) system was examined in the present study. The fabricated HPHXs were tested under the actual conditions and the measured data were used to study the performance of the existing AC system (System A) and AC system equipped with the double HPHX (System B) for a yearly operation through ...

متن کامل

Design and operation optimization of an air conditioning system through simulation: an hour-by-hour simulation study

In the present research, performance validation of a Heating, Ventilation, and Air Conditioning (HVAC) system operating in a library building was conducted. The operating HVAC system was studied in terms of the provided indoor air conditions and energy consumption level. The fieldwork measurements showed that the HVAC system is not capable of providing the desired indoor air conditions based on...

متن کامل

Sustainability of Automobile Air- Conditioning System Using Refrigerant R1234yf Instead of R134a

Air conditioning refrigerant R134a has value of global warming potential (GWP) 1300, which is much higher than MAC Directive (GWP below 150) passed in July 2006. This prompted a search for alternative refrigerant with GWP value less than 150. R1234yf is a new refrigerant which has lower GWP value of 4. Effect of blower speed has been compared and flammability issue of R1234yf has been addre...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009